Frcdwkswpr-No-Trfsw; Intrusion; Intrusion-Pswd; Login-Failure-Lockout - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.3.13 FRCDWKSWPR-NO-TRFSW

1.3.13 FRCDWKSWPR-NO-TRFSW
The Forced Switch to Protection Resulted in No Traffic Switch (FRCDWKSWPR-NO-TRFSW)
condition occurs when you perform a Force Switch to the protect port/card, and the protect port/card is
already active.
This transient condition does not result in a standing condition.

1.3.14 INTRUSION

The Invalid Login Username (INTRUSION) condition occurs when you attempt to log in with an invalid
user ID.
This transient condition does not result in a standing condition.

1.3.15 INTRUSION-PSWD

The Security Intrusion Attempt Detected (INTRUSION -PSWD) condition occurs when you attempt to
log in with an invalid password.
This transient condition does not result in a standing condition.

1.3.16 LOGIN-FAILURE-LOCKOUT

The Invalid Login–Locked Out (LOGIN-FAILURE-LOCKOUT) condition occurs when you attempt to
log into a locked account.
This transient condition does not result in a standing condition.

1.3.17 LOGIN-FAILURE-ONALRDY

The Security: Invalid Login–Already Logged On (LOGIN-FAILURE-ONALRDY) condition occurs
when you attempt to log into a node where you already have an existing session and a
Single-User-Per-Node (SUPN) policy exists.
This transient condition does not result in a standing condition.

1.3.18 LOGIN-FAILURE-PSWD

The Invalid Login–Password (LOGIN-FAILURE-PSWD) condition occurs when you attempt to log in
with an invalid password.
This transient condition does not result in a standing condition.

1.3.19 LOGIN-FAILURE-USERID

The Invalid Login–Username (LOGIN-FAILURE-USERID) condition occurs when a user login (CTC,
Cisco Transport Manager [CTM], or TL1) fails because the login username is not present on the node
database. You must log in again with an existing user ID.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-6
Chapter 1
Transient Conditions
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents