Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2090
No nodes selected. Please select the node(s) on which to store
the profile(s).
EID-2091
Unable to switch to node {0}.
EID-2092
General exception error.
EID-2093
Not enough characters in name. {0}
EID-2094
Password and confirmed password fields do not match.
EID-2095
Illegal password.
{0}
EID-2096
The user must have a security level.
EID-2097
No user name specified.
EID-2099
Ring switching error.
EID-2100
Please select at least one profile to delete.
EID-2101
Protection switching error.
EID-2102
The forced switch could not be removed for some circuits. You
must switch these circuits manually.
EID-2103
Error upgrading span.
EID-2104
Unable to switch circuits back as one or both nodes are not
reachable.
EID-2106
The node name cannot be empty.
EID-2107
Error adding {0}, unknown host.
EID-2108
{0} is already in the network.
EID-2109
The node is already in the current login group.
EID-2110
Please enter a number between 0 and {0}.
EID-2111
This node ID is already in use. Please choose another.
EID-2113
Cannot set extension byte for ring.
{0}
EID-2114
Card communication failure. Error applying operation.
EID-2115
Error applying operation.
{0}
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-8
Chapter 1
Description
You must select one or more nodes on
which you can store the profile.
CTC is unable to switch to the specified
node.
CTC encountered a general exception error
while trying to complete the task.
The name must have a minimum of six
characters.
You must make sure the two fields have the
same password.
The password you entered is not allowed.
You must have an assigned security level to
perform this task.
You did not specify a user name.
There was an error during the ring switch.
You have not selected the profile to delete.
There was an error during the protection
switching.
The forced switch could not be removed for
some circuits. You must switch these
circuits manually.
There was an error during the span upgrade.
This error occurs during the path protection
span upgrade procedure.
You must supply a name for the node.
There was an error adding the specified
item.
The specified item exists in the network.
The node you are trying to add is already
present in the current login group.
You must enter a number in the range
between 0 and the specified value.
Select a node ID that is not in use.
CTC cannot set the BLSR/MS-SPRing
extension byte.
This error can occur during an attempt to
apply a BLSR protection operation to a line.
There was an error in applying the specified
operation.
Error Messages