Cldrestart; Clear The Cldrestart Condition - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
Step 4
Using optical test equipment, verify that proper receive levels are achieved. (For specific procedures to
use the test set equipment, consult the manufacturer.)
Step 5
Verify that the optical LAN cable is properly connected and attached to the correct port. For more
information about fiber connections and terminations, refer to the "Install Hardware" chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA.
If the fiber cable is properly connected and attached to the port, verify that the cable connects the port
Step 6
to another Ethernet device and is not misconnected to an OC-3 or OC-12 port. For more information
about fiber connections and terminations, refer to the "Install Hardware" chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide. For more information about
Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA Ethernet Card Software
Feature and Configuration Guide.
If you are unable to establish connectivity, replace the fiber cable with a new known-good cable. To do
Step 7
this, refer to the "Install Hardware" chapter in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Procedure Guide for procedures.
Step 8
If you are unable to establish connectivity, perform standard network or LAN diagnostics. For example,
trace the IP route, verify cable continuity using site practice, and troubleshoot any routers between the
node and CTC.
Step 9
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.38 CLDRESTART

The Cold Restart condition occurs when an Ethernet card is reseated or replaced, or when the
ONS 15310-CL or ONS 15310-MA power is initialized.

Clear the CLDRESTART Condition

If the condition is raised on the controller card, it should clear after booting. If the condition is raised on
Step 1
an Ethernet card, complete the
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA.
If the condition raised against an Ethernet card does not clear, complete the
Step 2
procedure on page 1-155
78-17235-01
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
for the card.
"Remove and Reinsert (Reseat) a Card" procedure on page
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.38 CLDRESTART
1-155.
"Physically Replace a Card"
1-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents