Clear The Lcas-Crc Condition; Lcas-Rx-Fail - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Note
Ethernet Card Software Feature and Configuration Guide.

Clear the LCAS-CRC Condition

Look for and clear any associated equipment failures, such as the EQPT alarm, on the receive node or
Step 1
transmit node.
Look for and clear any bit error rate conditions at the transmit node.
Step 2
If no equipment or SONET path errors exist, ensure that the remote node has LCAS enabled on the
Step 3
circuit by completing the following steps:
a.
b.
c.
d.
If the column does not say LCAS, complete the
Step 4
it in LCAS mode using the instructions in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Ethernet
Card Software Feature and Configuration Guide.
If the condition does not clear, log into the Technical Support Website at
Step 5
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.125 LCAS-RX-FAIL

The LCAS VCG Member Receive-Side-In Fail condition is raised against ML-100T-8 Ethernet cards
with LCAS-enabled VCG or software-enabled LCAS (SW-LCAS) VCG.
LCAS VCGs treat failures unidirectionally, meaning that failures of the transmit or receive points occur
independently of each other. The LCAS-RX-FAIL condition can occur on the receive side of an LCAS
VCG member for the following reasons:
The condition can be raised during provisioning operations on LCAS VCGs but should clear when the
provisioning is completed.
Software-enabled LCAS VCGs treat failure bidirectionally, meaning that both directions of a VCG
member are considered failed if either transmit or receive fails. The LCAS-RX-FAIL condition is raised
on these VCG members when a member receive side fails due to a SONET path failure.
78-17235-01
In node view, click the Circuits tab.
Choose the VCAT circuit and click Edit.
In the Edit Circuit window, click the General tab.
Verify that the Mode column says LCAS.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: STSTRM, VT-TERM
SONET path failure (a unidirectional failure as seen by the receive side).
VCAT member is set out of group at the transmit side, but is set in group at the receive side.
VCAT member does not exist at the transmit side but does exist and is in group at the receive side.
"Delete a Circuit" procedure on page 1-156
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.125 LCAS-RX-FAIL
and recreate
1-83