Test The Ethernet Card; Perform A Facility Loopback On An Intermediate-Node Oc-N Port - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.6.3 Perform a Facility Loopback on an Intermediate-Node OC-N Port

Test the Ethernet Card

Complete the
Step 1
replace it with a known-good one.
Caution
Removing a card that currently carries traffic on one or more ports can cause a traffic hit. To avoid this,
perform an external switch if a switch has not already occurred. Refer to the procedures in the
"1.10.1 Protection Switching, Lock Initiation, and Clearing" section on page
information, refer to the "Maintain the Node" chapter in the Cisco ONS 15310-CL and
Cisco ONS 15310-MA Procedure Guide.
Resend test traffic on the loopback circuit with a known-good card.
Step 2
If the test set indicates a good circuit, the problem was probably the defective card. Return the defective
Step 3
card to Cisco through the RMA process. Contact Cisco Technical Support (1 800 553-2447).
Complete the
Step 4
Clear the terminal loopback on the port before testing the next segment of the network circuit path:
Step 5
a.
b.
c.
d.
e.
f.
Clear the terminal loopback circuit before testing the next segment of the network circuit path:
Step 6
a.
b.
c.
d.
Step 7
Complete the
page
1.6.3 Perform a Facility Loopback on an Intermediate-Node OC-N Port
Performing the facility loopback test on an intermediate node OC-N port (which carries the Ethernet
circuit) isolates whether this node is causing circuit failure. Complete the
on an Intermediate-Node OC-N Port" procedure on page
The CE100T-8 Ethernet card only supports point-to-point configurations and is not directly implicated
Note
in the intermediate node testing.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-32
"Physically Replace a Card" procedure on page 1-155
"Physically Replace a Card" procedure on page 1-155
Double-click the CE100T-8 card with the terminal loopback in the source node.
Click the Maintenance > Loopback tabs.
Select None from the Loopback Type column for the port being tested.
Select the appropriate state (IS; OOS,DSBLD; OOS,MT) in the Admin State column for the port
being tested.
Click Apply.
Click Yes in the confirmation dialog box.
Click the Circuits tab.
Choose the loopback circuit being tested.
Click Delete.
Click Yes in the Delete Circuits dialog box. Do not check any check boxes.
"1.6.3 Perform a Facility Loopback on an Intermediate-Node OC-N Port" procedure on
1-32.
Chapter 1
General Troubleshooting
for the suspected bad card and
1-148. For more
for the defective card.
"Create a Facility Loopback
1-33.