Clear The Pdi-P Condition - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
A PDI-P condition reported on an OC-3 or OC-12 port supporting an ONS 15310-CL or ONS 15310-MA
Ethernet card circuit could result from the end-to-end Ethernet link integrity feature of the Ethernet card.
If the link integrity is the cause of the path defect, it is typically accompanied by the
(EQPT)" alarm on page 1-36
is the case, clear the TPTFAIL and CARLOSS alarms to resolve the PDI-P condition.
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector.
Warning
Do not stare into the beam directly with optical instruments. Viewing the laser output with certain
optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of
100 mm could pose an eye hazard. Statement 1056
Warning
Use of controls, adjustments, or performing procedures other than those specified could result in
hazardous radiation exposure. Statement 1057

Clear the PDI-P Condition

Step 1
Verify that all circuits terminating in the reporting card are in an active state by completing the following
steps:
a.
b.
c.
After determining that the port is active, ensure that the signal source to the card reporting the alarm is
Step 2
working.
If traffic is affected, complete the
Step 3
Deleting a circuit can affect existing traffic.
Caution
Recreate the circuit with the correct circuit size. Refer to the "Create Circuits" chapter in the
Step 4
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide for procedures.
Step 5
If the circuit deletion and re-creation does not clear the condition, verify that there is no problem with
the far-end OC-3 or OC-12 port providing STS payload to the reporting card.
Step 6
If the condition does not clear, confirm that the cross-connect between the OC-3 or OC-12 port and the
reporting port is good.
Step 7
If the condition does not clear, clean the far-end optical fiber according to site practice. If no site practice
exists, complete the procedure in the "Maintain the Node" chapter in the Cisco ONS 15310-CL and
Cisco ONS 15310-MA Procedure Guide.
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA.
78-17235-01
reported against one or both Ethernet ports terminating the circuit. If this
Click the Circuits tab.
Verify that the Status column lists the port as active.
If the Status column lists the port as incomplete, wait 10 minutes for the ONS 15310-CL or
ONS 15310-MA to initialize fully. If the incomplete state does not change after full initialization,
log into the Technical Support Website at http://www.cisco.com/techsupport for more information
or call Cisco TAC to report a Service-Affecting (SA) problem (1 800 553-2447).
"Delete a Circuit" procedure on page
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0