Cisco ONS 15200 Installation, Setup, and Test Manual Hardware Release 1.1 January 2002 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Customer Order Number: DOC-7813765=...
Page 2
INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. For the purposes of the provisions hereinafter, Cisco shall mean Cisco Photonics, Inc. as well as the other groups of Cisco Systems, Inc. No part of this document may be used or reproduced, transmitted, transcribed, or otherwise copied in any form or by any means -- graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without prior written permission of Cisco.
C H A P T E R 2.1 Shipment Verification 2.1.1 ONS 15200 Shipping Container Label 2.1.2 Preliminary Inventory Check 2.1.3 Reporting Damage 2.2 Site Preparation 2.3 Unpacking Procedure: Unpack the ONS 15252 Multichannel Units Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 4
Procedure: Install an ONS 15201 SCU Dual-Lug Ground Connection 3-22 Procedure: Install an ONS 15201 SCU Ground Strip Connection 3-23 3.5.2 Install the ONS 15201 SCU Power 3-23 Procedure: Connect the Power Using AC-to-DC Power Supplies 3-23 Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 5
3.9.2 Channel Addition Using an ONS 15201 SCU 3-58 Procedure: Add an ONS 15201 SCU to the Ring 3-58 Turn Up and Test C H A P T E R 4.1 Equipment Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 6
B.1 ONS 15200 Network Configuration B.2 ONS 15252 Multichannel Unit Turn Up and Test B.3 ONS 15201 Single-Channel Unit Turn Up and Test B.4 ONS 15200 System Span Test I N D E X Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 7
Installing a Line module in an ONS 15252 MCU 3-33 Figure 3-25 Installing a Hub Filter module in an ONS 15252 MCU 3-35 Figure 3-26 Installing a Bridge module in an ONS 15252 MCU 3-36 Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 8
ONS 15201 SCU CLIP Module A side and B side with attenuators 4-16 Figure 4-7 ONS 15201 SCU in a daisy-chain configuration 4-18 Figure 4-8 ONS 15200 system span test connection (hub configuration) 4-20 Cisco ONS 15200 Installation, Setup, and Test Manual viii 78-13765-01...
Page 9
Table B-14 ONS 15201 SCU DWDM Receive Data Table B-15 ONS 15201 SCU Client Transmit Data Table B-16 ONS 15201 CLIP Switchmode Table B-17 ONS 15200 System Span Test Procedure Checklist Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 10
ONS 15200 Remote Span DWDM Transmit and Receive Measurements Table B-20 ONS 15252 MCU DWDM Receive Measurements B-10 Table B-21 ONS 15200 DWDM Receive Measurements B-10 Table B-22 ONS 15200 CLIP Switchmode B-11 Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
For additional information about the ONS 15200 system, refer to the following documents: Cisco ONS 15200 Product Description • • Cisco ONS 15200 Module Handbook Cisco ONS 15200 Maintenance Manager Installation and Operations Guide • • Cisco ONS 15200 Web Interface Software User Manual Cisco ONS 15200 Command Line Interface Manual •...
The following sections explain how to obtain documentation from Cisco Systems. World Wide Web You can access the most current Cisco documentation on the World Wide Web at the following URL: http://www.cisco.com Translated documentation is available at the following URL: http://www.cisco.com/public/countries_languages.shtml...
If you are reading Cisco product documentation on Cisco.com, you can submit technical comments electronically. Click Leave Feedback at the bottom of the Cisco Documentation home page. After you complete the form, print it out and fax it to Cisco at 408 527-0730.
Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to the following URL to register: http://www.cisco.com/register/...
Obtaining Technical Assistance If you cannot resolve your technical issues by using the Cisco TAC Web Site, and you are a Cisco.com registered user, you can open a case online by using the TAC Case Open tool at the following URL: http://www.cisco.com/tac/caseopen...
Page 16
About this Manual Obtaining Technical Assistance Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
C H A P T E R Safety Summary This chapter provides safety considerations for operating the Cisco ONS 15200 system. 1.1 Critical Safety Warnings Do not perform cabling on an electrically-live system. Ensure that all power is removed from the Warning shelf before continuing with this procedure.
Exclude any unauthorized personnel from the immediate laser radiation area during service and • installation when there is a possibility that the system may become energized. Consider the immediate service area to be a temporary laser-controlled area. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
1-3. Both labels have a yellow background. The triangle is placed above the text. In addition, small warning triangles and warning text are located close to the DWDM IN and OUT ports. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Assume that all solid-state electronic devices are ESD-sensitive. • Ensure that you are grounded with a grounded wriststrap or equivalent while working with • ESD-sensitive devices. Transport, store, and handle ESD-sensitive devices in static-safe environments. • Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
When you receive ONS 15200 system equipment at the installation site, immediately verify that the shipment is correct. Cisco does not recommend shipping equipment that is mounted in racks. To ship equipment from one Note site to another, pack the equipment in the original box.
Compare the packing list information with the alphanumeric information provided on the shipping labels. The packing list and shipping labels should contain the same information. If there are any discrepancies between the shipping label information and the packing list information, call the Cisco Technical Assistance Center (TAC) at 1-877-323-7368.
Clearance Required Bay access needed for maintenance Front access only, 482 mm (19 in.) Back clearance to bays 15 cm (6 in.) Clearance to open equipment covers 16 cm (6.4 in.) Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
• Leave equipment packed until it is needed for immediate installation. • Store packed equipment in the temperature and environmental conditions described in the Cisco ONS 15200 Product Description. • After unpacking the equipment, save and store the packaging material in case the equipment must be returned.
Carefully remove the protective foam packing material from the module(s). If any optical adapters are included in the container, remove them and save them for use while installing Step 3 the module front-panel optical fiber jumper cables (Chapter 3, “Installation”). Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 26
Chapter 2 Pre-Installation Procedures Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
The instructions in this section primarily address the installation of the ONS 15252 MCUs, ONS Note 15201 SCUs, and modules supplied by Cisco Systems. When installing racks, electrical wiring, raceways, and other equipment not covered in this manual, you should follow all local, state, federal, or international (if applicable) codes and regulations.
• Plugs for optical adapters (SC, MU) • Fiber holder (included in the MCU accessory kit) • • Tie wraps Chapter 4 lists the items required for turn up and test. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
It is vital that the ONS 15252 MCU, ONS 15252 fan unit, and ONS 15201 SCU are properly grounded. The grounding points on the ONS 15200 units are located as follows: Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
3-2. The location of the fan unit grounding points is shown in Figure 3-3. Figure 3-2 Ground points on the ONS 15252 MCU and ONS 15201 SCU ONS 15252 ONS 15201 Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
The ONS 15252 Release 1.0.1 includes a fan unit. Before using the Release 1.0.1 shelf, you must install the fan unit. Do not use the fan unit with a Release 1.0 shelf. See the Cisco ONS 15200 Product Description for more information about the fan unit.
NAM does not have a faceplate label. The Release 1.0.1 shelf requires the Release 1.0.1 NAM. You can also use Release 1.0.1 NAMs in the Release 1.0 shelf. See the Cisco ONS 15200 Module Handbook for more information about the NAM.
During the ONS 15252 MCU installation, two people are required to lift and hold the unit in position. Caution Align eight M6 cage nuts in the equipment rack. Figure 3-4 shows an example of an equipment rack, Step 1 with the cage nuts shaded in gray. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
The shelf assembly comes preset for installation in a 485 mm (19-in.) rack, but you can use extension brackets to convert it to a 584.2 mm (23-in.) rack. You will need two 13 RU extension brackets (P/N: 700-13268) for this procedure. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
“Install the ONS 15252 MCU Fiber Cable” procedure on page 3-18. Procedure: Remove the ONS 15252 MCU Transport Crossbeam from the Passive Optical Shelf Door Step 1 Open the passive optical shelf door. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
“Shelf Version Considerations” procedure on page 3-5. Do not install the fan unit in a Release 1.0 shelf. Cisco does not recommend or support running the Caution Release 1.0 shelf with a fan unit. Equipment damage may result. For more information about shelf versions, see the “Shelf Version Considerations”...
Use a multimeter that is set to read ohms to test the ground connection. The display on the multimeter should be less than 5 ohms. If the display is more than 5 ohms, tighten or reconnect the ground connection and test it again. Cisco ONS 15200 Installation, Setup, and Test Manual 3-11 78-13765-01...
You can replace the filter in the fan unit without removing the fiber organizer. Replacing the filter does not affect traffic. Warning Do not insert your fingers into the fan tray while the fans are running. Cisco ONS 15200 Installation, Setup, and Test Manual 3-12 78-13765-01...
ONS 15252 MCU ground cable can be either a single or dual lug as shown in Figure 3-11. You can also ground the MCU using the ground strip (P/N 72-2755) shown in Figure 3-12. Cisco ONS 15200 Installation, Setup, and Test Manual 3-13 78-13765-01...
Use a socket wrench to firmly tighten the M6 nut on the grounding pin. The attached ground cable should Step 4 look similar to the one shown in Figure 3-13. Cisco ONS 15200 Installation, Setup, and Test Manual 3-14 78-13765-01...
Step 3 Use a socket wrench to firmly tighten the M6 nuts on the grounding pins. The attached ground cable Step 4 should look like the one in Figure 3-14. Cisco ONS 15200 Installation, Setup, and Test Manual 3-15 78-13765-01...
Route the ground strip to the grounding pin where the M6 nut and washer were removed. Step 2 Attach the ground strip to the grounding pin with the M6 nut and washer removed in Step 3 Step Cisco ONS 15200 Installation, Setup, and Test Manual 3-16 78-13765-01...
Align and connect the power cable to the PS-2 (Power Supply 2) connector (left side) on the MCU backplane as shown in Figure 3-15. Step 5 Tie-wrap the power cable to the MCU as shown in Figure 3-15. Cisco ONS 15200 Installation, Setup, and Test Manual 3-17 78-13765-01...
Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15252 Caution MCU. The ONS 15252 MCU Client Layer Interface Port (CLIP) modules and the DWDM interface port use SC fiber connectors. Cisco ONS 15200 Installation, Setup, and Test Manual 3-18 78-13765-01...
(LMs). The receive port is labeled “IN” and the transmit port is labeled “OUT.” Cisco recommends that you label the client-side transmit and receive fiber and A-side and B-side DWDM fibers at each end of the fiber span to avoid confusion with cables that are similar in appearance.
Align the SCU with the equipment rack and cage nuts. Step 2 Step 3 Insert the SCU into the equipment rack. Step 4 Connect the SCU to the equipment rack with four M6 screws. Cisco ONS 15200 Installation, Setup, and Test Manual 3-20 78-13765-01...
Procedure: Install an ONS 15201 SCU Single-Lug Ground Connection Remove one M6 nut and washer from one of the grounding pins located on the SCU backplane as shown Step 1 Figure 3-17. Cisco ONS 15200 Installation, Setup, and Test Manual 3-21 78-13765-01...
Firmly tighten the M6 nuts on the grounding pins with a socket wrench. Step 4 Step 5 Connect the other end of the ground cable to a reliable earth ground. Cisco ONS 15200 Installation, Setup, and Test Manual 3-22 78-13765-01...
Align the connector on the power cable with the PS-1 power connector on the rear of the SCU. Figure 3-18 shows the power cable connector. Note Do not splice DC leads. Cisco ONS 15200 Installation, Setup, and Test Manual 3-23 78-13765-01...
Step 3 Insert the power cable connector into the PS-2 power supply connector. Step 4 Hand-tighten the power cable connector to firmly mate it to the PS-2 connector. Cisco ONS 15200 Installation, Setup, and Test Manual 3-24 78-13765-01...
3.5.3 Install the ONS 15201 Fiber Cable Always use the supplied ESD wristband when working with an ONS 15201. Caution ONS 15201 SCU client and DWDM interface use SC fiber connectors. Cisco ONS 15200 Installation, Setup, and Test Manual 3-25 78-13765-01...
3-21 for clarification. Cisco recommends that you label the client side transmit and receive fibers and A-side and B-side DWDM fibers at each end of the fiber span to avoid confusion with cables that are similar in appearance.
Page 53
Before making the necessary interconnections, connect the grounding wrist strap. Note Clean all optical connectors and keep them protected with caps prior to connection. Cisco ONS 15200 Installation, Setup, and Test Manual 3-27 78-13765-01...
15252 MCU (Slot 17). Step 2 Carefully insert the NCB module in the NCB module slot as shown in Figure 3-20. Be sure the NCB module connector and the backplane connector mate correctly. Cisco ONS 15200 Installation, Setup, and Test Manual 3-28 78-13765-01...
Be sure the CIM connector and the backplane connector mate correctly. Step 3 Use a slot or Phillips screwdriver to tighten the CIM retaining screws. Figure 3-21 shows the CIM installed in the ONS 15252 MCU. Cisco ONS 15200 Installation, Setup, and Test Manual 3-29 78-13765-01...
CLIP module in the ONS 15252 MCU. Step 4 Step 5 Install a CLIP module slot cover for each empty CLIP module slot. Figure 3-22 illustrates an ONS 15252 MCU with three CLIP modules installed. Cisco ONS 15200 Installation, Setup, and Test Manual 3-30 78-13765-01...
To open the MCU passive optical shelf, pull up on the door latches located on the left and right sides of Step 1 the door and pull gently towards you. Figure 3-23 illustrates an ONS 15252 MCU with the passive optical shelf door open. Cisco ONS 15200 Installation, Setup, and Test Manual 3-31 78-13765-01...
Make sure the crossbar at the back of the passive optical shelf and the groove in the back of the LMs fit together. Step 4 Push the button at the bottom front of the LMs and snap the LMs into place. Cisco ONS 15200 Installation, Setup, and Test Manual 3-32 78-13765-01...
Connection Module Y in Two ONS 15252 MCUs” procedure on page 3-38. Any Dummy Filter modules (DFMs), as described in the “Install the Dummy Network Adaptation • Module in the ONS 15252 MCU” procedure on page 3-45. Cisco ONS 15200 Installation, Setup, and Test Manual 3-33 78-13765-01...
Page 60
HFM located in the MCU passive optical shelf. Once the HFMs are installed Step 4 in the passive optical shelf, the MCU should appear as illustrated in Figure 3-25. Cisco ONS 15200 Installation, Setup, and Test Manual 3-34 78-13765-01...
Carefully slide each side of the BM into the passive optical shelf. Be sure the passive optical shelf Step 2 crossbeam and the slot on the bottom of each side of the BM connect properly. Cisco ONS 15200 Installation, Setup, and Test Manual 3-35 78-13765-01...
Connection Module Y in Two ONS 15252 MCUs” procedure on page 3-38. Position the TM in the passive optical shelf at the end of the row of HFMs. Step 1 Cisco ONS 15200 Installation, Setup, and Test Manual 3-36 78-13765-01...
Step 6 Snap the CMX into place by pushing the retainer located at the bottom of the CMX. Step 7 Remove the dust plugs located on the CMX duplex MU-MU adapter. Cisco ONS 15200 Installation, Setup, and Test Manual 3-37 78-13765-01...
Remove a TM from the passive optical shelf of the first ONS 15252 MCU. Position the CMY (Figure 3-28) in the passive optical shelf of the first MCU where you removed the Step 4 Cisco ONS 15200 Installation, Setup, and Test Manual 3-38 78-13765-01...
Snap the DFM into place by pressing the retainer button located at the bottom front of the DFM. Step 3 Repeat Step – until the passive optical shelf is filled (Figure 3-29). Step 4 Cisco ONS 15200 Installation, Setup, and Test Manual 3-39 78-13765-01...
Connect the LM MU duplex fiber jumper connector to the duplex MU adapter of the HFM closest to the Step 4 Remove the dust plugs from the optical-fiber jumper cable connector in the HFM. Step 5 Cisco ONS 15200 Installation, Setup, and Test Manual 3-40 78-13765-01...
(with a BM module installed). Figure 3-30 The ONS 15252 MCU passive optical shelf after the modules are connected Cisco ONS 15200 Installation, Setup, and Test Manual 3-41 78-13765-01...
Procedure: Install the Network Adaptation Module in the ONS 15252 MCU Cisco builds NAM modules per customer design specifications. If you plan to install multiple NAMs, verify that the NAM splitter ratio (50/50, 90/10, 10/90, 100/0, or 0/100) matches the requirements of the associated CLIP module.
11–13 for protected traffic. Use the labeling on the fiber to ensure that the A side and the Step 14 B side of the node are not interchanged (Figure 3-32). Cisco ONS 15200 Installation, Setup, and Test Manual 3-43 78-13765-01...
Do not install fiber with sharp bends. The radius of all bends must be at least 35 mm (1.4 in.). Step 16 Insert the fiber into the lateral grooves and snap the HFM back into place (Figure 3-33). Cisco ONS 15200 Installation, Setup, and Test Manual 3-44 78-13765-01...
Step 1 Carefully insert the DNAM into the slot. Be sure the DNAM connector and the backplane connector mate Step 2 correctly, and that no fibers are pinched in the process. Cisco ONS 15200 Installation, Setup, and Test Manual 3-45 78-13765-01...
Step 4 The ONS 15252 MCU with all modules installed and cover lid shut is shown in Figure 3-34. Figure 3-34 An installed ONS 15252 MCU Dummy Network Adaptation module Cisco ONS 15200 Installation, Setup, and Test Manual 3-46 78-13765-01...
Left cover Use a slot or Phillips screwdriver to loosen the retaining screws on the CFM cover lid. The positions of Step 3 the retaining screws are shown in Figure 3-36. Cisco ONS 15200 Installation, Setup, and Test Manual 3-47 78-13765-01...
Align the four holes in CFM case with the four CFM standoffs inside the SCU. When properly aligned, the CFM standoffs fit in the holes in the CFM case. Step 9 Fasten the CFM to the CFM standoffs with four retaining screws. Cisco ONS 15200 Installation, Setup, and Test Manual 3-48 78-13765-01...
Figure 3-44 show the connection information for each configuration. Figure 3-38 CFM for an unprotected channel (100/0 or 0/100) Figure 3-39 CFM for a protected channel (90/10, 10/90, or 50/50) Cisco ONS 15200 Installation, Setup, and Test Manual 3-49 78-13765-01...
Figure 3-40 90/10 split ratio (protected) connections Side B Side A Rx A CLIP Rx B Fusion splice Figure 3-41 10/90 split ratio (protected) connections Side A Side B Rx B CLIP Rx A Fusion splice Cisco ONS 15200 Installation, Setup, and Test Manual 3-50 78-13765-01...
Rx A CLIP Rx B Fusion splice Figure 3-43 0/100 split ratio (unprotected) connections for a CFM Side A Side B CLIP Rx B (not used) Rx A Fusion splice Cisco ONS 15200 Installation, Setup, and Test Manual 3-51 78-13765-01...
Clean and inspect the connectors on the fiber. Connect the fiber to the CLIP module optical connectors in accordance with the labels located on the Step 7 cables, starting with the receivers. Cisco ONS 15200 Installation, Setup, and Test Manual 3-52 78-13765-01...
You may combine the two different network objects as long as the total CAN bus length is less than 22 meters and the following rules apply: Note You can obtain one-meter (3.3 ft.) and five-meter (16.4 ft.) bus cables from Cisco (P/N 72-2654 and 72-2790, respectively). •...
Slots 15 and 16 of the MCU backplane (Figure 3-47). When leaving the factory, the two jumpers are set to 00. When adding MCUs to a single CAN bus, reset Cisco ONS 15200 Installation, Setup, and Test Manual 3-54 78-13765-01...
Step 1 Step 2 Remove the common cover for the CLIPs. Remove the blank front panel from the first slot on the right side of the installed CLIP modules. Step 3 Cisco ONS 15200 Installation, Setup, and Test Manual 3-55 78-13765-01...
Clean and inspect the fiber connectors of the new HFM. Step 7 Connect the new HFM to the adjacent HFM. Remove the dust caps from the fiber connectors of the second HFM (installed in Step Step 8 Cisco ONS 15200 Installation, Setup, and Test Manual 3-56 78-13765-01...
Arrange the fibers from the NAM in a smooth curve on top of the passive optical shelf. Snap the HFM back into place after you insert the fibers. Step 5 Cisco ONS 15200 Installation, Setup, and Test Manual 3-57 78-13765-01...
Enter. switchmode automatic Type to quit the CLIP module. exit Repeat Steps a–e for all CLIP modules. Install the new SCU (ATO) in the equipment rack. Step 2 Cisco ONS 15200 Installation, Setup, and Test Manual 3-58 78-13765-01...
Page 85
Connect the B-side IN and OUT ports of the other node to the A-side OUT and IN ports of the first node. Connect the client ports of the new SCU to the appropriate client equipment. Step 7 Cisco ONS 15200 Installation, Setup, and Test Manual 3-59 78-13765-01...
Page 86
Chapter 3 Installation Cisco ONS 15200 Installation, Setup, and Test Manual 3-60 78-13765-01...
Patch cord MU-SC (2) – Optical adapter SC simplex (2) – Optical adapter MU simplex (2) – • To manage an SCU, Maintenance Manager software and hardware (P/N 800-16721) installed on a Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
CAN accessory kit (p/n 800-20162-01, includes the CAN board, CAN cable, and CAN LAN cable) – Cisco ONS 15200 Maintenance Manager CD-ROM (p/n 85-2510-01) software installed on a PC – Crossover Ethernet cable for direct connection to the NCB (optional) 4.2 ONS 15200 Network Configuration...
On the Connect To dialog box, choose COM1 from the Connect Using drop-down list. Click OK. On the COM1 Properties dialog box, choose the port settings shown in Table 4-1 on page 4-4. Click Choose File > Properties. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
At the NCB:= prompt, type and press Enter. ipconf <ipaddr> <subnet> <gateway> Reboot the system for the changes to take effect. At the NCB:= prompt, type and press Enter. Step 7 reboot Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 91
Set the unit ID of the NCB module. This step is necessary for the NCB to scan the network for nodes. At the NCB:> prompt, type and press Enter. configure network Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
If you are planning to use an MU attenuator, insert the attenuator in the middle port on the CLIP interface (labeled with the down arrow). Table 4-2 ONS 15200 Wavelength Plan Channel Number Frequency (THz) Wavelength (nm) 192.3 1558.98 192.5 1557.36 Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 93
Your network planner can provide the following values: expected output power, maximum, and Note minimum. Actual transmit power on the LM OUT port must fall within the range provided by the network planner. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Record the attenuated power level for each channel in Table B-8 on page B-5. Insert the attenuated fiber-optical cable into the B-side IN port (Figure 4-3). Repeat Steps a–c on the A side. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
(see the ± formula and explanation below). The actual receive power should be 2.5 dB of the expected receive power. Formula: ERp = MTp – (HFM x 0.5 – 2.5) Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
CLIP module (Slot 2). Repeat until all CLIP modules are daisy-chained together with the last CLIP module’s OUT port returning to the test set, as shown in Figure 4-4. Cisco ONS 15200 Installation, Setup, and Test Manual 4-10 78-13765-01...
If the network design does not provide optical protection, skip the “Check Optical Protection” procedure on page 4-12 and proceed to the “Test the Bit Error Rate” procedure on page 4-12. Cisco ONS 15200 Installation, Setup, and Test Manual 4-11 78-13765-01...
To test bit error rate on unprotected modules, clear all errors on the test set and run BER tests error free Step 17 for 15 minutes. Complete Step Table B-4 on page B-2. Cisco ONS 15200 Installation, Setup, and Test Manual 4-12 78-13765-01...
Connect a laptop to the management access (MA) port located on the ONS 15201 SCU using the PCCAN Step 1 cable, CAN interface cable, and the PCMCIA LAPcan board (Figure 4-5). For more information, refer to the Cisco ONS 15200 Maintenance Manager Installation and Operations Guide. Cisco ONS 15200 Installation, Setup, and Test Manual 4-13 78-13765-01...
Table B-13 on page B-7. Repeat Steps a–b for the B side and record the information in Table B-13 on page B-7. The network planner provides the expected output power. Note Cisco ONS 15200 Installation, Setup, and Test Manual 4-14 78-13765-01...
Disconnect the power meter from the client side output and run a fiber from the client OUTPUT interface Step 9 to the receive of the signal generator. Do not remove any fibers. Note Cisco ONS 15200 Installation, Setup, and Test Manual 4-15 78-13765-01...
Reconnect the fiber jumper cable pulled in Step 12. The Standby green light for the B-side should be illuminated, and the A side Active LED should remain illuminated. Complete Step Table B-11 on page B-7. Cisco ONS 15200 Installation, Setup, and Test Manual 4-16 78-13765-01...
Connect the receive of the signal generator to the bottom SCU client-side OUTPUT port. Daisy-chain client INPUT and OUTPUT ports of all other SCUs together as shown in Figure 4-7. Cisco ONS 15200 Installation, Setup, and Test Manual 4-17 78-13765-01...
Page 104
Disconnect the jumper cable on the B-side INPUT port of the bottom SCU in loopback mode. Reconnect the B-side jumper cable and verify that all protected SCUs identify the A side as Active and the B side as Standby. Cisco ONS 15200 Installation, Setup, and Test Manual 4-18 78-13765-01...
Continue until the ring is completed by connecting the fiber from the last node A-side OUTPUT port to the INPUT port of the originating MCU B-side INPUT port (Figure 4-8). Cisco ONS 15200 Installation, Setup, and Test Manual 4-19 78-13765-01...
Procedure: Test the Bit Error Rate for Unprotected Channels Continue with the following steps to test the bit error rate for unprotected channels. If you have one or more protected channels, proceed with Step Cisco ONS 15200 Installation, Setup, and Test Manual 4-20 78-13765-01...
Clear all errors on the test set and run BERT error free for two hours. Complete Step Table B-17 on page B-8. Step 16 Reset the original switch mode settings recorded in Table B-22 on page B-11. It is important to perform this step. Note Cisco ONS 15200 Installation, Setup, and Test Manual 4-21 78-13765-01...
Page 108
Chapter 4 Turn Up and Test Cisco ONS 15200 Installation, Setup, and Test Manual 4-22 78-13765-01...
CAN bus (high) to MA system CANL CAN bus (low) to MA system TERM_INSERT +4.5 VDC, 72ohms (Reserved, part of the CAN bus control) RS-232 transmit Table 5-2 shows the CIM internal bus (INT BUS) connections. Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
ONS 15201 Management Access Connections Pin Number Function Signal Not used 0 VDC reference for CAN bus and part of CAN bus relay control CANL_RET CAN bus return (low) from MA system Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Client OUT (All CLIP modules) Client output signal (from the ONS 15252 MCU) A-side LM IN A-side DWDM input signal (toward the ONS 15252 MCU) A-side LM OUT A-side DWDM output signal (from the ONS 15252 MCU) Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
A-side DWDM output signal (from the ONS 15201 SCU) B-side SCU IN B-side DWDM input signal (toward the ONS 15201 SCU) B-side SCU OUT B-side DWDM output signal (from the ONS 15201 SCU) Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
A P P E N D I X Acronyms The following acronyms and other abbreviations are used in this manual: A-side add/drop multiplexer B-side battery distribution bay bit error rate Bridge module Celsius control area network Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 114
CLIP Client Line Interface Port module Connection Module X Connection Module Y decibels decibels referenced to 1 milliwatt Dummy FIlter module DNAM Dummy Network Adaptation module DWDM dense wavelength division multiplexing Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 115
Acronyms Electronic Industries Association electromagnetic compatibility electromagnetic interference European telecommunication standard Fahrenheit Federal Communications Commission Food and Drug Administration file transfer protocol Hub Filter module International Electrotechnical Commission International Telecommunications Union Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 116
Multichannel Unit Maintenance Manager Network Adaptation module Network Control Board module network element NEBS Network Building System NFPA National Fire Protection Association OADM optical add/drop multiplexer optical networking system optical spectrum analyzer Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 117
Appendix A Acronyms personal computer interface power distribution panel QDBS database system proprietary protocol optical receiver Single-Channel Unit synchronous digital hierarchy Subnetwork Manager synchronous transfer mode Technical Assistance Center Transport Control Protocol Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 118
Appendix A Acronyms Telecommunication Industry Association Termination module optical transmitter World Wide Web Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
A P P E N D I X Acceptance Test Plan This chapter contains tables and checklists sheets to use during the first turn up and test of a Cisco ONS 15200 system. When you are performing the turn up and test procedures in Chapter 4, “Turn Up...
BER test error-free for 15 minutes—B-side Table B-5 ONS 15252 MCU CLIP Data CLIP MU Transmit Slot Serial Channel Frequency Wavelength Power Attenuator Splitter Number Number Number (THz) (nm) (dB) (8 or 0 dB) Ratio Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
A-Side ONS 15252 MCU Wavelength and Output Power Data Output Power Wavelength Output Measured A-Side Wavelength Reading from Output Power Within Network Slot Expected Frequency Meter Power Measured Planner Range Number (nm) (nm) Expected (dBm) (dBm) Pass or Fail Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
B-Side ONS 15252 MCU Wavelength and Output Power Data Wavelength Output Power Reading Output Measured Within B-Side Wavelength from Frequency Output Power Network Planner Slot Expected Meter Power Measured Range Number (nm) (nm) Expected (dBm) (dBm) Pass or Fail Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
A Side (dBm) (dBm) Fail B-Side (dBm) (dBm) Table B-9 ONS 15252 MCU Client Transmit Data Pass or Fail Measured Client Valid Range Slot Number Transmit Power (dBm) -8 to -10 dBm Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Appendix B Acceptance Test Plan Table B-9 ONS 15252 MCU Client Transmit Data (continued) Table B-10 ONS 15252 MCU CLIP Switchmode CLIP Serial Number Switchmode Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Table B-14 ONS 15201 SCU DWDM Receive Data DWDM DWDM DWDM DWDM Attenuated A-Side A-Side Attenuated B-Side B-Side Pass Pass Reading Expected Measured Reading Expected Measured A Side (dBm) (dBm) Fail B Side (dBm) (dBm) Fail Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Table B-18 ONS 15200 Hub Span DWDM Transmit and Receive Measurements Measured Measured Measured Measured 15252 MCU DWDM A DWDM A DWDM B DWDM B Slot # Channel Side Tx Side Rx Side Tx Side Rx Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 127
Table B-19 ONS 15200 Remote Span DWDM Transmit and Receive Measurements Measured Measured Measured Measured DWDM A DWDM A DWDM B DWDM B Location Channel Side Tx Side Rx Side Tx Side Rx Cisco ONS 15200 Installation, Setup, and Test Manual 78-13765-01...
Page 128
DWDM DWDM DWDM Measured A-Side A-Side Measured B-Side B-Side Within Remote Within Range Measured Expected Range Measured Expected Pass or Location Number (dBm) (dBm) Pass or Fail (dBm) (dBm) Fail Cisco ONS 15200 Installation, Setup, and Test Manual B-10 78-13765-01...
Page 129
Remote Within Range Measured Expected Range Measured Expected Pass or Location Number (dBm) (dBm) Pass or Fail (dBm) (dBm) Fail Table B-22 ONS 15200 CLIP Switchmode CLIP Serial Number Switchmode Cisco ONS 15200 Installation, Setup, and Test Manual B-11 78-13765-01...
Page 130
Appendix B Acceptance Test Plan Cisco ONS 15200 Installation, Setup, and Test Manual B-12 78-13765-01...