Create The Facility Loopback On An Intermediate-Node Oc-N Port - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.3.4 Perform a Facility Loopback on an Intermediate-Node OC-N Port

Create the Facility Loopback on an Intermediate-Node OC-N Port

Connect an optical test set to the port you are testing:
Step 1
a.
b.
c.
Use CTC to set up the facility loopback circuit on the port being tested:
Step 2
a.
b.
c.
d.
e.
f.
Confirm that the newly created circuit appears on the Circuits tab list as a two-way circuit.
Step 3
Note
Create the facility loopback on the destination port being tested:
Step 4
a.
b.
c.
d.
e.
f.
g.
Continue with the
Step 5
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-18
If you just completed the
"1.3.3 Perform a Terminal Loopback on a Source-Node OC-N Port"
procedure on page
1-16, leave the optical test set connected to the OC-N port in the source node.
If you are starting the current procedure without the optical test set connected to the OC-N port, use
appropriate cabling to attach the Tx and Rx terminals of the optical test set to the port you are
testing.
Adjust the test set accordingly.
Click the Circuits tab and click Create.
Give the circuit an easily identifiable name, such as OCN1toOCN3.
Set circuit Type and Size to the normal preferences, such as STS and STS1.
Verify that Bidirectional is checked and click Next.
In the Circuit Source dialog box, fill in the source Node, Slot, Port, and Type where the test set is
connected and click Next.
In the Circuit Destination dialog box, fill in the destination Node, Slot, Port, and Type (the OC-N
port in the intermediate node) and click Finish.
It is normal for a
1.7.158 LPBKFACILITY (OCN)
The condition clears when you remove the loopback.
Go to the node view of the intermediate node:
From the View menu, choose Go To Other Node.
Choose the node from the drop-down list in the Select Node dialog box and click OK.
In node view, double-click the controller card (15310-CL-CTX or CTX2500) in the intermediate
node.
Click the Maintenance > Optical > Loopback > Port tabs.
Select OOS,MT from the Admin State column.
Select Facility from the Loopback Type column.
Click Apply.
Click Yes in the confirmation dialog box.
Note
It is normal for a
1.7.158 LPBKFACILITY (OCN)
setup. The condition clears when you remove the loopback.
"Test the Facility Loopback Circuit" procedure on page
Chapter 1
General Troubleshooting
condition to appear during a loopback setup.
condition to appear during loopback
1-19.
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents