Bkupmemp; Clear The Bkupmemp Alarm; Blsrosync; Carloss (Ce100T) - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting

1.7.34 BKUPMEMP

The Primary Nonvolatile Backup Memory Failure alarm refers to a problem with the 15310-CL-CTX or
CTX2500 flash memory. The alarm occurs when the 15310-CL-CTX or CTX2500 has one of four
problems:
The BKUPMEMP alarm can also cause the
by BKUPMEMP, complete the following procedure to clear the BKUPMEMP and the EQPT alarms.

Clear the BKUPMEMP Alarm

Verify that the controller card (15310-CL-CTX or CTX2500) is powered and enabled by confirming a
Step 1
lighted ACT LED on front of the system.
Complete the
Step 2
Wait ten minutes to verify that the card you reset completely reboots. The ACT LED should be green.
If the 15310-CL-CTX or CTX2500 does not reboot successfully, or the alarm has not cleared, call
Step 3
Cisco TAC (1 800 553-2447).

1.7.35 BLSROSYNC

The BLSROSYNC alarm is not used in the ONS 15310 platforms in this release. It is reserved for
development.

1.7.36 CARLOSS (CE100T)

The Carrier Loss alarm is raised on CE-Series cards in Mapper mode when the port is In-Service (IS) state
and if there is no carrier signal. Circuit need not be present to raise the alarm. In releases prior to 6.01 the
Carrier Loss alarm is raised on CE-100T-8 cards in Mapper mode when there is a circuit failure due to link
integrity. It does not get raised when a user simply puts the port in the In-Service and Normal (IS-NR) service
state.
78-17235-01
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
Flash manager fails to format a flash partition.
Flash manager fails to write a file to a flash partition.
Problem at the driver level.
Code volume fails cyclic redundancy checking (CRC, a method to verify for errors in data
transmitted to the 15310-CL-CTX or CTX2500).
"Soft- or Hard-Reset a Controller Card" procedure on page
Default Severity: Major (MJ), Service-Affecting (SA)
SONET Logical Object: CE100T
"EQPT" alarm on page
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.34 BKUPMEMP
1-52. If the EQPT alarm is caused
1-154.
1-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents