1.10.2 Circuits Remain in PARTIAL Status

Table 1-20
Possible Problem
During an automatic
transition, some
path-level defects
and/or alarms were
detected on the circuit.
One end of the circuit is
not properly terminated.

View the State of Circuit Nodes

Step 1
Click the Circuits tab.
From the Circuits tab list, select the circuit with the OOS-PARTIAL status condition.
Step 2
Click Edit. The Edit Circuit window appears.
Step 3
In the Edit Circuit window, click the State tab.
Step 4
The State tab window lists the Node, CRS End A, CRS End B, and CRS State for each of the nodes in
the circuit.
1.10.2 Circuits Remain in PARTIAL Status
Symptom
Table 1-21
Table 1-21
Possible Problem
The MAC address
changed.

1.10.3 AIS-V on Unused 15310-CL-CTX Card VT Circuits

Symptom
Table 1-22
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-62
Circuit in Partial Status (continued)
Solution
Determine which node in the circuit is not changing to the desired state.
Refer to the
Log into the circuit node that did not change to the desired state and examine
the circuit for path-level defects, improper circuit termination, or alarms.
Refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure
Guide for procedures to clear alarms and change circuit configuration
settings.
Resolve and clear the defects and alarms on the circuit node and verify that
the circuit transitions to the desired state.
Circuits remain in the PARTIAL status.
describes the potential cause of the symptom and the solution.
Circuits Remain in PARTIAL Status
Solution
Repair the circuits. Refer to the "Manage Circuits" chapter of the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide for
instructions.
An incomplete circuit path causes an alarm indications signal (AIS).
describes the potential cause of the symptom and the solution.
"View the State of Circuit Nodes" procedure on page
Chapter 1
General Troubleshooting
1-62.
78-17235-01