Ctc Card Resetting And Switching; Soft- Or Hard-Reset An Ethernet Or Electrical Card In Ctc; Soft- Or Hard-Reset A Controller Card - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.10.2 CTC Card Resetting and Switching

1.10.2 CTC Card Resetting and Switching
Avoid soft resetting more than one ONS 15310-MA card at a time. Instead, issue a soft reset command
Caution
for a single card, then wait until CTC shows the card is back up. You can then issue a soft reset on another
card if needed. Completing soft resets in sequence helps to avoid unexpected traffic hits.

Soft- or Hard-Reset an Ethernet or Electrical Card in CTC

The hard-reset option is enabled on CE-100T-8 and ML-100T-8 cards only when the card is placed in
Note
the OOS-MA,MT service state.
Note
Hard-resetting a traffic card causes a traffic hit in the ONS 15310-CL or ONS 15310-MA. To preserve
traffic flow, perform a traffic switch in the
section on page 1-148
Soft-resetting an ML-100T-8 Ethernet traffic card causes a traffic hit. To preserve traffic flow, perform
Note
a traffic switch in the
page 1-148
Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA Ethernet Card Software
Feature and Configuration Guide.
Step 1
Log into a node on the network. If you are already logged in, continue with
In node view, position the cursor over the card slot reporting the alarm.
Step 2
Right-click the card. Choose Hard-Reset Card or Soft-Reset Card from the shortcut menu.
Step 3
Click Yes in the Resetting Card dialog box.
Step 4

Soft- or Hard-Reset a Controller Card

Caution
Hard-resetting a 15310-CL-CTX or CTX2500 can cause a traffic hit. A soft reset causes a traffic hit only
if a provisioning change or firmware upgrade has occurred (or in the multiple soft-reset circumstance
previously noted). To preserve traffic flow, perform a traffic switch in the
Lock Initiation, and Clearing" section on page 1-148
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-154
In the Circuits on Span dialog box, the switch state for all circuits is Clear. Unprotected circuits do
not switch.
as appropriate.
"1.10.1 Protection Switching, Lock Initiation, and Clearing" section on
as appropriate. Soft-resetting a CE-100T-8 card is errorless. For more information about
"1.10.1 Protection Switching, Lock Initiation, and Clearing"
as appropriate.
Chapter 1
Alarm Troubleshooting
Step
2.
"1.10.1 Protection Switching,
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma