Chapter 1
Error Messages
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
WID-5051
Unable to transition port state indirectly because the port
aggregates OCH CC circuits: if the port state should be
changed, edit it directly via port provisioning
EID-5052
The operation is not valid for the connection type
EID-5053
The operation cannot be performed because the connection is
under test access
EID-5054
TL1 Tunnel Open Failed: {0}
EID-5055
Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
EID-5056
This PPC cannot be deleted because one or more circuits are
provisioned over it.
EID-5057
Adding last node not completed yet.
Please wait before trying to add new node.
EID-5058
OCHNC Upgrade is applicable only to bidirectional circuits.
EID-5059
OCHNC upgrade failed.
One or more communication failures occurred during the
operation.
EID-5060
OCHNC upgrade partially failed.
One or more communication failures occurred during the
operation.
Create the OCH CC manually.
EID-5061
Overhead circuit source and destination must reside on the
same shelf.
EID-6000
Platform does not support power monitoring thresholds
EID-6001
One of the XC cards has failures or is missing.
EID-6002
One of the XC cards is locked.
EID-6003
Unable to create OSC termination.
Ring ID already assigned.
EID-6004
Unable to perform a system reset while a BLSR ring is
provisioned on the node.
EID-6005
Could not assign timing references:
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference
- BITS-2 is not supported on this platform.
78-17235-01
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Description
Refer to the warning message text.
You may have selected the incorrect switch.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.
Refer to the error message text.
Refer to the error message text.
CTC encountered a complete failure while
upgrading optical channel network
connection.
CTC encountered a partial failure while
upgrading an optical channel network
connection.
Refer to the error message text.
Refer to the error message text.
Check whether all the cross-connect cards
are installed and working.
Unlock the cross-connect card.
Enter a new ID for the ring.
Remove the BLSR from the node and
continue with the reset procedure.
Refer to the error message text.