Cisco ONS 15310-CL Troubleshooting Manual page 310

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5033
Unable to load profile.
Error decoding characters.
EID-5034
Unable to load profile.
File format error.
EID-5035
Unable to load profile.
File read error.
EID-5036
The GNE Host Name {0} is invalid.
EID-5037
Provisionable patchcords cannot be created between
transponder trunk ports and mux/demux ports on the same
node.
EID-5038
Provisionable patchcords created between transponder trunk
ports and mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
EID-5039
Provisionable patchcords created between transponder trunk
ports and mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.
EID-5040
Provisionable patchcords between OC3/OC12 ports and
mux/demux ports are not supported.
EID-5041
Provisionable patchcords between non-colored OCn trunk ports
and mux/demux ports are not supported.
EID-5042
Provisionable patchcords created between OCn trunk ports and
mux/demux ports must use the same wavelength:
{0} is not equal to {1}.
WID-5043
Warning: line card is only provisioned:
wavelength compatibility check is skipped.
EID-5044
Virtual link can be used only for OCH trail circuits.
EID-5045
Virtual link does not have wavelength available.
WID-5046
Warning: if you select "Use OCHNC Direction" your circuit
will be limited to nodes prior to release 07.00.
EID-5047
Provisionable patchcords between OC3/OC12 ports are not
supported.
EID-5048
Provisionable patchcords between non-colored OCn trunk ports
are not supported.
EID-5049
Provisionable patchcords between non-colored OCn trunk ports
and mux/demux ports are not supported.
EID-5050
Cannot find Element Model:
{0}
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-34
Chapter 1
Description
CTC detected an error while decoding
characters and could not load the profile.
CTC detected an error and could not load
the profile.
CTC could not read the file and is therefore
unable to load the profile.
The specified host name is invalid. CTC
could not resolve the host name to any valid
IP address
You must create provisionable patchcords
between transponder trunk ports and
mux/demux ports that are on different
nodes.
Wavelengths used by provisionable
patchcords for transponser trunk ports and
mux/demux ports must be the same.
Transmitter and receiver port wavelengths
are not equal. Provision the receiver and
transmitter wavelengths on transmitter and
receiver ports respectively.
Refer to the error message text.
Refer to the error message text.
Wavelengths used by provisionable
patchcords for OC-N trunk ports and
mux/demux ports must be the same.
Refer to the warning message text.
Refer to the error message text.
Set wavelengths for the virtual link and
proceed.
Refer to the warning message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
The specified Element Model cannot be
located.
Error Messages
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma