Chapter 1
Error Messages
Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5018
{0} is {1} node and cannot be added to {2} network.
EID-5019
Manual mode for this equipment does not support an expected
string consisting of all null characters. Please change the
expected string or the path trace mode.
WID-5020
Unable to transition port state indirectly because the port
aggregates low order circuits: if the port state should be
changed, edit it directly via port provisioning
EID-5021
No nodes are selected. Please choose a node.
WID-5022
Warning: Ethergroup circuits are stateless (i.e., always in
service).
Current state selection of {0} will be ignored.
EID-5023
Unable to communicate with node.
Operation failed.
EID-5024
Overhead circuit will not be upgraded.
WID-5025
The path targeted for this switch request is already active. The
switch request can be applied, but traffic will not switch at this
time.
EID-5026
A 15600 cannot serve as the primary or secondary node in a 4
Fiber {0} circuit. Please change your ring and/or node
selections so that a 15600 is not chosen as the primary or
secondary node in this 4 Fiber {1} circuit.
WID-5027
The {0} Edit Window for {1} has been closed due to significant
provisioning changes. These changes may only be transitory, so
you may re-open the {0} Edit Window to view the updated
state.
WID-5028
Warning: This operation should only be used to clean up rolls
that are stuck. It may also affect completeness of the circuit.
Continue with deletion?
EID-5029
A software downgrade cannot be performed to the selected
version while an SSXC card is inserted in this shelf. Please
follow the steps to replace the SSXC with a CXC card before
continuing the software downgrade.
EID-5030
A software downgrade cannot be performed at the present time. Try the software downgrade later.
WID-5031
Cancelling a software upgrade during standby TSC clock
acquisition may result in a traffic outage.
EID-5032
Error accepting load.
78-17235-01
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
Description
You cannot add the node {0} of type {1} to
the host node of type {2}. This prevents you
from hosting both SONET and SDH nodes
in the same session.
The path trace mode does not support
strings that consist of null characters. You
must either change the expected string or
the path trace mode.
Refer to the warning message text.
Refer to the error message text.
Refer to the warning message text.
CTC encountered a network
communication error. Connectivity between
CTC and the NE was disrupted, either
transiently or permanently.
Refer to the error message text.
Refer to the warning message text.
Refer to the error message text.
Re-open the BLSR/MS-SPRing edit
window to view the updated state of the
ring.
Refer to the warning message text.
Refer to the error message text.
Refer to the warning message text.
Refer to the error message text.