1.3.27 RMON-RESET

1.3.27 RMON-RESET
The RMON Histories and Alarms Reset Reboot (RMON-RESET) condition occurs when the
time-of-day settings on the 15310-CL-CTX or CTX2500 card are increased or decreased by more than
five seconds. This invalidates all the history data and RMON must restart. It can also occur when you
reset a card.

1.3.28 SESSION-TIME-LIMIT

The Session Time Limit Expired (SESSION-TIME-LIMIT) condition occurs when a login session
exceeds the time limit and you are logged out of the session. You must log in again.

1.3.29 SFTWDOWN-FAIL

The Software Download Failed (SFTDOWN-FAIL) condition occurs when the system fails to download
the required software.
An incorrect input that points to the wrong place or file, network issues, or a bad (corrupt) package can
cause this failure. Retrying the operation with the correct name/location will usually succeed. If network
issues persist, you must contact the network lab support.

1.3.30 USER-LOCKOUT

The User Locked Out (USER-LOCKOUT) condition occurs when the system locks an account because
of a failed login attempt. To proceed, the administrator must unlock the account or the lockout time must
expire.

1.3.31 USER-LOGIN

The Login of User (USER-LOGIN) condition occurs when you begin a new session by verifying your
User ID and password.
This transient condition does not result in a standing condition.

1.3.32 USER-LOGOUT

The Logout of User (USER-LOGOUT) condition occurs when you stop a login session by logging out
of your account.
This transient condition does not result in a standing condition.

1.3.33 WKSWBK

The Switched Back to Working (WKSWBK) condition occurs when traffic switches back to the working
port/card in a nonrevertive protection group.
This transient condition does not result in a standing condition.