1.7.165 MANRESET
Clear the MAN-REQ Condition
Complete the
Step 1
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.165 MANRESET
A User-Initiated Manual Reset condition occurs when you right-click a card in CTC and choose Reset.
Resets performed during a software upgrade also prompt the condition. The MANRESET condition
clears automatically when the card finishes resetting.
MANRESET is an informational condition and does not require troubleshooting.
Note
1.7.166 MANSWTOINT
The Manual Switch To Internal Clock condition occurs when the NE timing source is manually switched
to an internal timing source.
MANSWTOINT is an informational condition and does not require troubleshooting.
Note
1.7.167 MANSWTOPRI
The Manual Switch To Primary Reference condition occurs when the NE timing source is manually
switched to the primary timing source.
Note
MANSWTOPRI is an informational condition and does not require troubleshooting.
1.7.168 MANSWTOSEC
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-108
"Initiate a 1+1 Manual Switch Command" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: NE-SREF
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF