1.10.4 Generic Signal and Circuit Procedures
Step 7
If a row shows a state other than IS, click in the column cell to display the drop-down list and select IS.
Click Apply.
Step 8
Note
Clear an EC-1 Port Loopback
Step 1
Log into a node on the network. If you are already logged in, continue with
Step 2
Double-click the reporting card in CTC to display the card view.
Click the Maintenance > EC1 > Loopback tabs.
Step 3
In the Loopback Type column, determine whether any port row shows a state other than None.
Step 4
If a row contains another state besides None, click in the column cell to display the drop-down list and
Step 5
select None.
In the Admin State column, determine whether any port row shows a state other than IS.
Step 6
If a row shows a state other than IS, click in the column cell to display the drop-down list and select IS.
Step 7
Click Apply.
Step 8
Note
Clear an Ethernet Card Loopback Circuit
This procedure applies to CE-100T-8 or ML-100T-8 cards.
Log into a node on the network. If you are already logged in, continue with
Step 1
Step 2
Double-click the reporting card in CTC to display the card view.
Step 3
Click the Maintenance > Loopback tabs.
Step 4
In the Loopback Type column, determine whether any port row shows a state other than None.
If a row contains another state besides None, click in the column cell to display the drop-down list and
Step 5
select None.
Step 6
In the Admin State column, determine whether any port row shows a state other than IS, for example,
OOS,MT.
If a row shows a state other than IS, click in the column cell to display the drop-down list and select IS.
Step 7
Step 8
Click Apply.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-158
If ports managed into IS administrative state are not receiving signals, the LOS alarm is either
raised or remains, and the port service state transitions to OOS-AU,FLT.
If ports managed into IS administrative state are not receiving signals, the LOS alarm is either
raised or remains, and the port service state transitions to OOS-AU,FLT.
Chapter 1
Alarm Troubleshooting
Step
2.
Step
2.
78-17235-01