Chapter 1
Alarm Troubleshooting

1.7.17 APS-PRIM-SEC-MISM

The Optimized 1+1 APS Primary Section Mismatch condition occurs on OC-N ports in an optimized
1+1 protection system if there is a mismatch between the primary section of the local node facility and
the primary section of the remote-node facility.

Clear the APS-PRIM-SEC-MISM Alarm

Ensure that the local node and remote-node ports are correctly provisioned the same way. For more
Step 1
information about optimized 1+1 configurations, refer to the "Turn Up Node" chapter in the
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC (1 800 553-2447).

1.7.18 AS-CMD

The Alarms Suppressed by User Command condition applies to the network element (NE object), a
single card, or a port on a card. It occurs when alarms are suppressed for that object and its subordinate
objects. For example, suppressing alarms on a card also suppresses alarms on its ports.
For more information about suppressing alarms, refer to the "Manage Alarms" chapter in the
Note
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.

Clear the AS-CMD Condition

For all nodes, in node view, click the Conditions tab.
Step 1
Click Retrieve. If you have already retrieved conditions, look under the Object column and Eqpt Type
Step 2
column and note what entity the condition is reported against—such as a port, slot, or shelf.
Determine whether alarms are suppressed for a port and if so, raise the suppressed alarms by completing
Step 3
the following steps:
a.
b.
78-17235-01
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: BPLANE, CE100T, DS1, DS3, EC1, EQPT, NE, OCN, PWR
DWDM Logical Objects: PPM, SHELF
If the condition is reported against a slot and card, alarms were either suppressed for the entire card
or for one of the ports. Note the slot number and continue with
If the condition is reported against the NE object, go to
Double-click the card to display the card view.
Click the Provisioning > Alarm Profiles > Alarm Behavior tabs and complete one of the following
substeps:
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.17 APS-PRIM-SEC-MISM
Step
3.
Step
7.