Eqpt-Miss; Erfi-P-Conn; Clear The Erfi-P-Conn Condition - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Chapter 1
Alarm Troubleshooting
Step 3
If the CTC reset does not clear the alarm, complete the
procedure on page 1-155
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15310-CL
Caution
or ONS 15310-MA.
If the physical reseat of the card fails to clear the alarm, complete the
Step 4
procedure on page 1-155
Note
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 5
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.59 EQPT-MISS

The Replaceable Equipment or Unit Missing alarm is reported against the fan tray within the
ONS 15310-CL or ONS 15310-MA. It indicates that the fan is not operational, or that the
ONS 15310-MA fan tray is not present. For an ONS 15310-CL, this alarm is not user-serviceable. For
the ONS 15310-MA, complete the fan tray replacement procedure located in the Cisco ONS 15310-CL
and Cisco ONS 15310-MA Procedure Guide.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.

1.7.60 ERFI-P-CONN

The Three-Bit (Enhanced) Remote Failure Indication (ERFI) Path Connectivity condition is triggered on
DS-1, DS-3, or VT circuits when the
page 1-140

Clear the ERFI-P-CONN Condition

Complete the
Step 1
procedure on page
78-17235-01
for the reporting card.
for the reporting card.
When you replace a card with the identical type of card, you do not need to make any changes
to the database.
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: FAN
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
SONET Logical Objects: STSMON, STSTRM
are raised on the transmission signal.
"Clear the UNEQ-P Alarm" procedure on page 1-143
1-140. This should clear the ERFI condition.
"Remove and Reinsert (Reseat) a Card"
"UNEQ-P" alarm on page 1-143
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1.7.59 EQPT-MISS
"Physically Replace a Card"
and the
"TIM-P" alarm on
and the
"Clear the TIM-P Alarm"