1.7.175 MEM-GONE

1.7.175 MEM-GONE
The Memory Gone alarm occurs when data generated by software operations exceeds the memory
capacity of the 15310-CL-CTX or CTX2500. The 15310-CL-CTX or CTX2500 cards which exceed the
memory capacity reboot to avoid failure of card operations.
Note
The alarm does not require user intervention. The MEM-LOW alarm always preceeds the MEM-GONE
alarm.

1.7.176 MEM-LOW

The Free Memory of Card Almost Gone alarm occurs when data generated by software operations is
close to exceeding the memory capacity of the 15310-CL-CTX or CTX2500. The alarm clears when
additional memory becomes available. If additional memory is not made available and the memory
capacity of the card is exceeded, CTC ceases to function.
The alarm does not require user intervention. If the alarm does not clear, log into the Technical Support
Note
Website at http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.177 MFGMEM

The Manufacturing Data Memory Failure alarm occurs when the electronically erasable programmable
read-only memory (EEPROM) fails on a card or component, or when the 15310-CL-CTX or CTX2500
cannot read this memory. EEPROM stores manufacturing data that a 15310-CL-CTX card uses to
determine system compatibility and shelf inventory status. Unavailability of this information can cause
less-significant problems.
To clear the MFGMEM alarm, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447) to report a
Service-Affecting (SA) problem.

1.7.178 NO-CONFIG

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-112
Default Severity: Major (MJ), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Objects: BPLANE, FAN, PPM
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)