Cisco ONS 15310-CL Troubleshooting Manual page 318

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-6137
Cannot disable multishelf.
EID-6138
Invalid LAN configuration.
EID-6139
Invalid card(s) present.
Please remove all non-MSTP cards and try again.
EID-6140
The shelf identifier for a subtended shelf cannot be provisioned
via CTC. It must be changed using the LCD.
EID-6143
DHCP server could not be changed.
EID-6144
The port provisioning cannot be changed when the port media
is Undefined.
1. EID-3159 can appear if you attempt to perform another switching operation within a certain time interval. This interval is an algorithm of three seconds
per working card in the protection group. The maximum interval is 10 seconds.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-42
Chapter 1
Description
Multishelf is not supported on equipment, is
already disabled, or modules on the shelf
are currently in use.
Verify the LAN configuration.
Non-DWDM cards cannot be added to an a
DWDM node. Remove the cards.
Refer to the error message text.
Refer to the error message text.
If the port is not pre-provisioned with the
type of media that is going to be inserted,
you cannot access any of the existing values
for the port.
Error Messages