Swtothird; Clear The Swtothird Condition; Sync-Freq; Clear The Sync-Freq Condition - Cisco ONS 15310-CL Troubleshooting Manual

Sonet multiservice platforms
Hide thumbs Also See for ONS 15310-CL:
Table of Contents

Advertisement

1.7.230 SWTOTHIRD

Step 2
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).
1.7.230 SWTOTHIRD
The Synchronization Switch to Third Reference condition occurs when the ONS 15310-CL or
ONS 15310-MA has switched to a third timing source (reference 3).

Clear the SWTOTHIRD Condition

Step 1
To clear the condition, clear alarms related to failures of the primary source, such as the
alarm on page 1-136
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.231 SYNC-FREQ

The Synchronization Reference Frequency Out Of Bounds condition is reported against any reference
that is out of the bounds for valid references. The login node fails the reference and chooses another
internal or external reference to use.

Clear the SYNC-FREQ Condition

Use an optical test set to verify the timing frequency of the line or BITS timing source and ensure that
Step 1
it falls within the proper frequency. For specific procedures to use the test set equipment, consult the
manufacturer. For BITS, the proper timing frequency range is approximately –15 PPM to 15 PPM. For
optical line timing, the proper frequency range is approximately –16 PPM to 16 PPM.
If the SYNC-FREQ condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.232 SYNCPRI

Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-136
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: EXT-SREF, NE-SREF
or the
"SYNCSEC" alarm on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: BITS, DS1, OCN
Default Severity: Minor (MN), Non-Service-Affecting (NSA) for EXT-SREF; Major (MJ),
Service-Affecting (SA) for NE-SREF
SONET Logical Objects: EXT-SREF, NE-SREF
Chapter 1
1-137.
Alarm Troubleshooting
"SYNCPRI"
78-17235-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-ma

Table of Contents