Table 1-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2043
This node is not selectable. Only the source node and nodes
attached to included spans (blue) are selectable. Selecting a
selectable node will enable its available outgoing spans.
EID-2044
This link may not be included in the required list. Constraints
only apply to the primary path. Each node may have a
maximum of one incoming signal and one outgoing link.
EID-2045
This link may not be included in the required list. Only one
outgoing link may be included for each node.
EID-2047
Error validating slot number. Please enter a valid value for the
slot number.
EID-2048
Error validating port number. Please enter a valid value for the
port number.
EID-2050
New circuit destroy failed.
EID-2051
Circuit cannot be downgraded. {0}
EID-2052
Error during circuit processing.
EID-2054
Endpoint selection error.
EID-2055
No endpoints are available for this selection. Please make
another selection.
EID-2056
Communication error. {0}
EID-2059
Node deletion Error. {0}
EID-2060
No PCA circuits found.
EID-2061
Error provisioning VLAN.
EID-2062
Cannot delete VLAN. No VLAN(s) are selected. Please select
a VLAN.
EID-2063
Cannot delete default VLAN.
EID-2064
Error deleting VLANs.
{0}
EID-2065
Cannot import profile. Profile "{0}" exists in the editor and the
maximum number of copies (ten) exists in the editor. Aborting
the import. The profile has already been loaded eleven times.
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-6
Chapter 1
Description
Refer to the error message text.
You must select only one link going in and
out of a node. Selecting more than one link
is contradictory to the path selection
algorithm.
Refer to the error message text.
There was an error due to an invalid slot
number.
There was an error due to an invalid port
number.
CTC could not destroy the new circuit.
The specified circuit cannot be
downgraded.
There was an error during the circuit
processing.
There was an error during the endpoint
selection.
This error occurs in the circuit creation
dialog only during a race condition that has
incorrectly allowed entities without
endpoints to be displayed in the
combination boxes.
An internal error occurred in Network
Alarm tab while synchronizing alarms with
the nodes.
There was an error during the node deletion.
CTC could not find any protection channel
access (PCA) circuits for this task.
There was an error defining the VLAN.
Refer to the error message text.
The selected VLAN is the default VLAN
and cannot be deleted.
There was an error deleting the specified
VLAN.
Cannot import the profile because the
profile has reached the maximum number of
copies in the editor.
Error Messages
78-17235-01