iDCS 500
TECHNICAL MANUAL
Display
Number/
LCD Display
Alm
Code
32
NOT USED
MJE06
33
NOT USED
MJE07
34
NOT USED
MJE08
35
Card Out
MNF01
36
Card In
MNF02
37
IPC Error
MNF03
38
Trunk Fault
MNF04
39
Trunk Recovery
MNF05
40
Trunk Disconnect
MNF06
41
Trunk Connect
MNF07
42
SMDR Over
MNF08
43
SMDR Under
MNF09
44
DSS Alarm
MNF10
46
SIO Out
MNF11
47
SIO In
MNF12
MMC: 852
Alarm
Notification
ON/OFF
OFF
FUTURE USE
OFF
FUTURE USE
OFF
FUTURE USE
A circuit card mounted in a universal slot has
been removed from service or is not recognized
ON/OFF
by the Main Control Processor
A circuit card mounted in a universal slot has
been returned to service.
ON/OFF
Inter
processor
occurred.
ON/OFF
Out of service trunk detected via loop detect.
Internal CODEC test.
ON/OFF
Alarm Data = Cabinet, Slot Port (C1,2)
Out of service trunk detected via loop detect as
out, is now operational.
ON/OFF
Out of service trunk detected via seizure of
trunk. External seizure test.
ON/OFF
Alarm Data = Cabinet, Slot Port (C1,2)
Out of service trunk recovered via seizure of
trunk External seizure test.
ON/OFF
Alarm Data = Cabinet, Slot Port (C1,2)
ON/OFF
SMDR buffer above 80% capacity.
ON/OFF
SMDR buffer below 80% capacity.
System capacity of 64 button DSS modules has
ON/OFF
been exceeded.
IO port has lost DTR
ON/OFF
IO port has regained DTR.
ON/OFF
PROGRAMMING
PART 2 AUGUST 2003
Display Definition
Alarm Data = Cabinet, Slot (C1,2)
-(S 1 through 9)
Alarm Data = Cabinet, Slot (C1,2)
(S 1 through 9)
communication
Alarm Data = Cabinet, Slot (C1,2)
(S 1 through 9)
(S1 through 9), (P1 through8)
Alarm Data = Cabinet-Slot Port (C1,2)
(S 1 through 9), (P1 through 8)
(S1 through 9), (P1 through 8)
(S1 through 9), (P1 through 8)
Alarm Data = SIO 1 through 4
Alarm Data = SIO 1 through 4