Samsung iDCS 500 Programming Manual page 373

Hide thumbs Also See for iDCS 500:
Table of Contents

Advertisement

iDCS 500
TECHNICAL MANUAL
MMC: 808
DESCRIPTION:
Provides a means to set the parameters needed to meet the requirements of a T1
span.
CODING FORMAT
0
AMI
Alternate Mark Inversion
1
B8ZS
Binary 8 Zero Substitution
SIGNALLING FORMAT
0
SF
Superframe
1
ESF
Extended Superframe
(BOM) used in the USA.
(HDLC) not used.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
ACTION
1. Press TRSF 808
Display shows
2. Press UP or DOWN key to make selection
Press RIGHT soft key to move cursor
3. Press UP or DOWN key to make selection
Press RIGHT soft key to make change and
return to step 1
4. Press RIGHT softkey to move cursor
Press UP or DOWN key to make selection
Press RIGHT softkey to move cursor
Press UP or DOWN key to make selection
Press RIGHT soft key to make change and
return to step 1
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
PROGRAMMING
PART 2 JUNE 2002
T1 PARAMETERS
DISPLAY
[701]T1 PARAMETERS
CODING: AMI
[701]T1 PARAMETERS
CODING: AMI
[701]T1 PARAMETERS
CODING: B8ZS
[701]T1 PARAMETERS
SIGNAL: SF
[701]T1 PARAMETERS
SIGNAL: ESF (BOM)
HOME
PAGE
Table of
Contents
HELP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents