iDCS 500
TECHNICAL MANUAL
Display
Number/
LCD Display
Alm
Code
01
POR Restart
MJA01
02
Soft Restart
MJA02
03
Mem Reset
MJA03
04
MCP Reset
MJA04
05
PCM Switching
MJA05
06
HDLC Com Error
MJB01
07
Memory Alarm
MJB02
08
DTMF Fault
MJC01
09
Tone Fault
MJC02
10
AA-DTMF Fault
MJC03
11
AA-DTMF Rec
MJC04
12
Sync Failure
MJD01
13
Sync Recovery
MJD02
14
NTWRK Event
MJD03
MMC: 852
ALARM KEY DISPLAYS
Alarm
Notification
ON/OFF
Main Control Processor (MCP) restart process
ON/OFF
has been executed via power on reset (POR).
Main Control Processor (MCP) restart process
ON/OFF
has been executed via button reset.
The system RAM has been cleared via
ON/OFF
manual programming (PCMMC or KPMMC)
resulting in a system reset.
The MCP has reset
ON/OFF
A fault has occurred in the Switching Control
ON/OFF
Alarm Data = Card(XXXX) Option board (X)
Communications to Expansion Control Pro-
ON/OFF
cessor lost or faulty.
A RAM diagnostic check error has occurred in
ON/OFF
the Main Control Processor (MCP).
An abnormal failure has occurred in the system
ON/OFF
DTMF resources.
Alarm Data = Card(XXXX) Option board (X)
An abnormal failure has occurred in the system
ON/OFF
tone resources.
Alarm Data = Card(XXXX) Option board (X)
An abnormal failure has occurred in one of the
system AA card DTMF resources.
ON/OFF
An abnormal fault reported in one of the
systems
ON/OFF
recovered.
Clocking on T1/PRI/BRI cards has become
asynchronous.
ON/OFF
Clocking on T1/PRI/BRI cards has become
ON/OFF
synchronous.
Alarm Data = Cabinet, Slot C1,2 S1 through 9
An Implausible event has occurred on the PRI
/BRI Network digital line. Protocols do not
ON/OFF
match or subscriber ID mismatches.
PROGRAMMING
PART 2 AUGUST 2003
Display Definition
Alarm Data= 01 through 07
Alarm Data = Cabinet, Slot, Port (C1,2)
(S1 through 9) (P1 through 8)
AA
card
DTMF
resources
Alarm Data = Cabinet, Slot, Port (C1,2)
(S1 through 9) (P1 through 8)
Alarm Data = Cabinet, Slot (C1,2)
(S1 through9)
Alarm Data = Cabinet, Slot (C1,2)
(S1 through 9)