TECHNICAL MANUAL
MMC: 432
DESCRIPTION:
This read only MMC will confirm the connection status of stations or trunks. Display
status actually displays the status of a station or trunk at the time requested. If a
conference is in progress with the selected trunk or station the display will show one
of the conference parties and an arrow ("). The technician or system administrator
can then display the next parties in the conference. If a station or trunk is in an idle
state the display will show "NONE". If the station or trunk selected is not a valid
selection the display will show "INVALID DATA". If the station or trunk is made busy
by the CPU the display will show "MADE BUSY". If the station is in busy state with
no other connection, the display will show "BUSY" only.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
TRSF
ACTION
Display trunk connection status
1.
Press TRF 432
2.
Enter station or trunk number.
Display show connection status
3.
Enter another station or trunk OR
press transfer to exit.
Display station connection status
1.
Press TRF 432
2.
Enter station or trunk number.
Display show connection status
CONNECTION STATUS
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to advance to next MMC
Exit
PART 2 JANUARY 2001
DISPLAY
DISPLAY STATUS
201 : IDLE
DISPLAY STATUS
702 : 227
DISPLAY STATUS
702 : 227
DISPLAY STATUS
_
:
DISPLAY STATUS
235 : 715