ALM
ALARM
CODE
MNF08
SIO TxQ Under
MNF07
E1 Out of Srv
MNF11
E1 In Service
MNF12
SIO Out
MNF13
SIO In
MNF14
TODC Error
MNF15
TSW Over Alarm
MNF16
PSU Alarm
MNF17
PSU Alarm Rec
MNF18
SLI Fault
MNF19
SLI Recovery
MNF20
PSUB Alarm
MNF21
DSS Alarm
MNF22
Phone Disconnect
MNF23
Phone Connect
MNF24
NOT USED
MMC: 851
DEFINITION
SIO Tx Queue under error has occurred in the MCP.
Alarm data = SIO number (SIO:x)
E1 Digital line status has been changed to out of service.
Alarm data = Cabinet, Slot (Cx-Syy)
E1 Digital line has been restored to normal service.
Alarm data = Cabinet, Slot (Cx-Syy)
IO port has lost DTR.
Alarm data = SIO number (SIO:x)
IO port has regained DTR.
Alarm data = SIO 1 through 6
Time of Day Clock in the MCP has erred.
TSW has been requested to exceed the capacity of available
time slots. Maximum 192 cabinet.
Alarm data = Cabinet, Slot (Cx-Syy)
Indicates there are over 56 ports in a cabinet with a single PSU
and more power is required.
Alarm data = Cabinet, Slot (Cx-Syy)
A second PSU has been recognized when added after the alarm
condition.
Alarm data = Cabinet, Slot (Cx-Syy)
An SLI card has been detected as out of service via an internal
CODEC test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
An SLI card detected as out of service has been detected as
recovered and is in service via internal CODEC test.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Indicates there are over 120 ports in a cabinet with two PSU.
Alarm data = Cabinet, Slot (Cx-Syy)
System capacity of 64 button DSS modules has been exceeded.
Indicates the Keyset is disconnected.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
Indicates the Keyset is connected.
Alarm data = Cabinet, Slot, Port (Cx-Syy-Pzz)
FUTURE USE