Appendix A
Catalyst 2955 Alarm Commands

alarm facility power-supply

Use the alarm facility power-supply global configuration command to set the alarm options for a
missing or failing power supply when the system is operating in dual power-supply mode. Use the no
form of the command to disable the specified setting.
Syntax Description
notifies
relay major
relay minor
syslog
Defaults
A power supply alarm message is stored but not sent to an SNMP server, to a relay, or to a syslog server.
Command Modes
Global configuration
Command History
Release
12.1(12c)EA1
Usage Guidelines
Power supply alarms are generated only when the system is in dual power-supply mode. When a second
power supply is connected, you must use the power-supply dual global configuration command to set
dual power-mode operation.
Before you use the notifies keyword to sent alarm traps to an SNMP host, you need to set up an SNMP
server by using the snmp-server enable traps global configuration command.
Examples
This example shows how to set the power-supply monitoring alarm to go to the minor relay circuitry:
Switch(config)# alarm facility power-supply relay minor
Related Commands
Command
power-supply dual
show alarm settings
snmp-server enable traps
OL-10102-01
alarm facility power-supply {notifies | relay {major | minor} | syslog}
no alarm facility power-supply {notifies | relay {major | minor} | syslog}
Send power supply alarm traps to a Simple Network Management Protocol
(SNMP) server.
Send the alarm to the major relay circuitry.
Send the alarm to the minor relay circuitry.
Send power supply alarm traps to a syslog server.
Modification
This command was introduced.
Description
Sets the switch to operate in dual power-supply mode.
Displays environmental alarm settings and options.
Enables the switch to send SNMP notification for various trap types to
the network management system (NMS).