Message content
Explanation
The device is a shared FC, so you need to change it on the PCI Device
Assignment screen.
LPAR manager
Aborts the specified process.
operation
What to do
Make the setting on the Shared FC Assignment screen.
Message content
Explanation
The device is a shared NIC, so you need to change it on the PCI
Device Assignment screen.
LPAR manager
Aborts the specified process.
operation
What to do
Make the setting on the VNIC Assignment screen.
Guest operating system might not remove USB devices safely.
Message content
Explanation
Indicates that connecting or disconnecting the device might have
failed.
LPAR manager
Only detaches the USB device, and stops changing the USB device
operation
assignment to other LPARs.
What to do
Assign the USB device to the LPAR again.
Message content
LPAR manager could not import Time Setting of SVP.
Explanation
Importing time from the management module failed.
LPAR manager
Aborts the specified process.
operation
What to do
Check if the management module version supports the NTP linkage.
Message content
LPAR manager is busy with another LPAR(X) activation process.
Explanation
During LPAR Activation processing, activation failed except for the
securing of resources.
LPAR manager
Aborts the specified process.
operation
What to do
Wait a moment and then retry the specified process.
Message content
Explanation
Operation is not available due to LPAR migration in execution.
LPAR manager
Aborts the specified process.
operation
What to do
Wait a while until LPAR migration is complete and then retry the
specified process.
Go to Shared FC Assign on Type=F & Schd=S.
Go to VNIC Assign on Type=T & Schd=S.
Force to detach.
LPAR manager is executing LPAR Migration,
Please try again after it is finished.