Hitachi Compute Blade 2000 User Manual page 1645

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(a) moduleConfigBlade group (3/25)
Object
No.
identifier
23
bladeInfoMa
.1.3.6.1.4.1
xCurrency
.116.5.39.2
.2.1.1.20
24
bladeInfoMa
.1.3.6.1.4.1
xPower
.116.5.39.2
.2.1.1.21
25
bladeInfoAm
.1.3.6.1.4.1
bientTempHi
.116.5.39.2
gher
.2.1.1.22
26
bladeInfoAm
.1.3.6.1.4.1
bientTempLo
.116.5.39.2
wer
.2.1.1.23
27
bladeInfoCP
.1.3.6.1.4.1
U0TempHigh
.116.5.39.2
er
.2.1.1.24
28
bladeInfoCP
.1.3.6.1.4.1
U0TempLow
.116.5.39.2
er
.2.1.1.25
29
bladeInfoCP
.1.3.6.1.4.1
U1TempHigh
.116.5.39.2
er
.2.1.1.26
30
bladeInfoCP
.1.3.6.1.4.1
U1TempLow
.116.5.39.2
er
.2.1.1.27
(*1)
"Not install" is shown if no server blade is installed; "Cannot get data" is shown if the
data cannot be obtained.
(*2)
"Not install" is shown if no server blade is installed; "Cannot get data" is shown if the
server blade data cannot be obtained. "Not support" is shown as the response in this
equipment.
(*3)
The response is "-1" if no server blade is installed, or if no partition exists.
(*4)
The response is "0" if no server blade or no processor is installed.
(*8)
With SMP configuration, when the primary blade location is specified in a partition, the
values of the entire partition are displayed; when a blade location other than the primary
one is specified, "0" is displayed.
OID
Syntax
Access
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
1594
Description
Shows the max current value of
the server blade installed in the
slot shown in #5. This value is
shown using the unit of 0.1A.
(*4)(*8)
Shows the rated power value of
the server blade installed in the
slot shown in #5. This value is
shown using the unit of 1W.
(*4)(*8)
Shows the upper temperature
threshold value of inlet air for
warning to the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
Shows the lower temperature
threshold value of inlet air for
warning to the server blade
installed in the slot shown in #5.
This value is always shown as 0.
Shows the upper temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
Shows the lower temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is always shown as 0.
Shows the upper temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is shown as 1 for
0.1°C. (*4)
Shows the lower temperature
threshold value of CPU for
warning in the server blade
installed in the slot shown in #5.
This value is always shown as 0.