Hitachi Compute Blade 500 Series Web Console Users Manual

Hitachi Compute Blade 500 Series Web Console Users Manual

Hide thumbs Also See for Compute Blade 500 Series:

Advertisement

Hitachi Compute Blade 500 Series
Web Console User's Guide
Document Organization
Product Version
Getting Help
Contents
MK-91CB500015-11

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi Compute Blade 500 Series

  • Page 1 Hitachi Compute Blade 500 Series Web Console User's Guide Document Organization Product Version Getting Help Contents MK-91CB500015-11...
  • Page 2 Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication.
  • Page 3: Table Of Contents

    System event log ..................2-182 Optional Physical WWN change log ............. 2-184 Optional Physical MAC change logs ............. 2-185 Operation logs ..................2-186 MAR logs ....................2-187 Environment log ..................2-188 Administration ....................2-189 Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 4 Language ....................2-203 Services ....................2-204 SNMP ......................2-210 E-Mail Notification ..................2-214 SC/BSM ..................... 2-217 HCSM ....................... 2-219 Hi-Track ....................2-222 Certificate ....................2-224 Syslog transfer ..................2-226 Login banner ..................... 2-226 Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 5: Preface

    This document provides site planning information for Compute Blade. Please read this document carefully, and maintain a copy for reference. Notice: The use of Compute Blade 500 series and all other Hitachi Data Systems products is governed by the terms of your agreement(s) with Hitachi Data Systems.
  • Page 6: Intended Audience

    Describes Web console operations. Referenced Documents • Hitachi Gigabit Fibre Channel Adapter USER'S GUIDE (BIOS/EFI Edition), MK-99COM009 • Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide, MK-91CB500068 • Hitachi Compute Blade 500 Series Management Module Setup Guide, MK-91CB500014 •...
  • Page 7: Document Conventions

    This term "Compute Blade" refers to all the models of the Compute Blade, unless otherwise noted. The Hitachi Virtualization Manager (HVM) name has been changed to Hitachi logical partitioning manager (LPAR manager, or LP). If you are using HVM based logical partitioning feature, substitute references to Hitachi logical partitioning manager (LPAR manager, or LP) with HVM.
  • Page 8: Convention For Storage Capacity Values

    Getting help The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: https://portal.hds.com. Comments Please send us your comments on this document: doc.comments@hds.com.
  • Page 9: Setting Up The Web Console

    Setting Up the Web Console This chapter describes prerequisites for the Web console. □ Prerequisites Setting Up the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 10: Prerequisites

    Items Specifications Flash player Adobe® Flash® Player version 10.2 or later Java software Required for Remote Console. See Hitachi Compute Blade 500 Series Remote Console User's Guide for details. Microsoft® Windows® Red Hat® Enterprise Linux® Browser Internet Explorer 7 or later Firefox 3.0 or later...
  • Page 11: Operating The Web Console

    Operating the Web Console This chapter describes Web console operations. □ Login/Logout □ Web console configuration □ Dashboard □ Resources □ Alerts □ Administration Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 12: Login/Logout

    Web console. • If your password is near expiration at login, a dialog box that warns you of the password expiration date appears. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 13: Logout

    You can change the setting in Menu bar > Action > Edit login account settings. Logout Click the Logout button, or select Log out in the File menu. In the Logout dialog box, click OK. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 14: Web Console Configuration

    To continue setting values, log into the Web console again. Web console configuration This section describes Web console configuration, features, and roles. Window configuration This subsection describes Web console window configuration. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 15 Logs out of the Web console. Global tab Dashboard Features on page Dashboard on page 2-12 Resources Resources on page 2-15 Alerts Alerts on page 2-182 Administration Administration on page 2-189 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 16: Features

    LPARs on this window as well. Switch Module Shows the operation status, Switch modules hardware information, and 0 – 3 configuration of a specified switch Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 17 Default Physical MAC address unique to hardware, an Optional Physical MAC address, and virtual MAC address, used by a mezzanine card installed in a server blade. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 18 Logs collected at a failure can be downloaded. Environment Log Shows the highest and lowest inlet/outlet temperatures per day. The history can be downloaded. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 19 Syslog transfer Shows and sets of syslog transfer. Login banner Displays and changes the settings for the login banner. Notes: Manages modules and resources installed. Manages modules installed. Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 20: Roles

    OS console of the server blades. The system unit has an embedded role shown in the following table, which cannot be changed or deleted. 2-10 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 21 LPAR manager License Chassis Security strength settings Chassis Alerts tab System Event Log Chassis Optional Physical WWN Change Log Chassis Optional Physical MAC Change Log Chassis 2-11 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 22: Dashboard

    Using the Dashboard tab This subsection describes items shown on the Dashboard tab. 2-12 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 23 A module installed in the location is set in maintenance mode. Table 2-8 Chassis status (Summary table) Icon Description Normal A module is running properly. 2-13 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 24 [Blank]: This event has been checked. Checked events are not included in the number of the summary. [!]: This event is not checked. Unchecked events are included in the number of the summary. 2-14 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 25 Modules This subsection describes items shown for Modules. All modules Selecting All modules from the navigation tree on the left shows the outline of all modules. 2-15 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 26 ID, and shutting down the system unit. Chassis summary Click the Action combo box on the upper right to show items that allows you to control the chassis. 2-16 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 27 Front panel Sets the front panel to release from maintenance mode. Maintenance mode Import System Imports system settings. See Hitachi Compute Blade 500 Series Settings Management Module Setup Guide for details. Edit silent mode Sets the chassis silent mode settings. Need to install the module settings that supports the silent mode to enable silent mode.
  • Page 28 Condition tab Click the Condition tab in the Chassis Information panel title bar to show the following items. 2-18 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 29 OFF: Front panel LID (Identification LED) turns off. Maintenance classification Shows the chassis maintenance classification. Normal: Operates normal maintenance mode Long life: Operates long life support mode 2-19 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 30 Edit Chassis ID Changes chassis IDs that consists of up to 20 characters: Printable alphanumeric characters, symbols, and spaces. But ignores a space or spaces at the beginning and the end. 2-20 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 31 Shows values of FRU and sensor for the server chassis. Front panel tab Click the Front panel tab in the Chassis Information panel to show the following item. 2-21 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 32 Click the USB devices tab in the Chassis Information panel to show the following items. Click the Action button > Unmount to unmount a selected USB device. 2-22 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 33 LCD Touch Panel Console: LCD touch console CDROM Device: CD-ROM/DVD-ROM drive Disk Device: Hard Disk drive Mass storage: mass storage (Example: Flash memory) USB version Shows USB version, 1.1 or 2.0. 2-23 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 34 The mode will be automatically cancelled in about two hours after the mode is set. 2-24 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 35 OFF: The server blade is powered off including in sleep state. -----: No server blade is installed or a non-primary server blade is installed. Shows an LID (Identification LED) state among the following states. 2-25 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 36 Some running OSs may not be powered off due to the OS settings. Check the OS settings before using this item. 2-26 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 37 OFF: The server blade is powered off including in sleep state. -----: No server blade is installed or a non-primary server blade is installed. Host name This item is not supported. This item is not supported. 2-27 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 38: Server Blade

    Setting and operation of BMC, EFI, mezzanine cards onboard, and LPAR are also available on the window. 2-28 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 39 Register a license key to enable the TPM. Registration of the license, Lisence key. choose enter the license key directly, or to input a license key file. 2-29 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 40 Server Blade No. Server Blade No. is shown. Backup Current LP Settings LP firmware LPAR manager firmware version is shown. Note: Server Blade No. and LPAR manager firmware version is shown. 2-30 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 41 The backup file used to restore LPAR manager settings (LPAR manager configuration information) is shown. Browse Select the backup file used to restore LPAR manager settings (LPAR manager configuration information). 2-31 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 42 LPAR manager settings (LPAR manager configuration information) is shown. Table 2-32 Action buttons at the bottom Item Description Back Restore LP Settings dialog is shown. Restore LPAR manager Settings (LPAR manager configuration information). 2-32 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 43 Server Blade No.and LPAR manager firmware version is shown. Table 2-34 Action buttons at the bottom Item Description Initialize LPAR manager Settings (LPAR manager configuration information). Cancel Close Initialize LP Settings dialog. 2-33 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 44 Shows the server blade operation state. Normal: Server blades in a normal state. Warning: Server blades in a warning state. Check the contents in the event list. 2-34 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 45 No Information: No Smart Configure is performed after the server chassis was powered on or the server blade configuration changed. In Progress: Smart Configure is being performed automatically or manually. 2-35 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 46 Issue NMI Issues NMI (Non-Maskable Interrupt) to the OS running on the selected server blade. Run Smart Performs Smart Configure on the selected server Configure blade. 2-36 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 47 Shows the total number of CPU slots. Memory [MB] Shows the total amount of memory in megabytes. I/O Card Mezzanine 1 Shows the mezzanine card model name. 2-37 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 48 Shows the latest version of LPAR manager firmware of version available. Nameplate power (W) Shows the server blade nameplate power in watts. Weight (kg) Shows the server blade weight. 2-38 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 49 SMP configuration only when the primary server blade is selected. I/O Card Mezzanine 1 Shows the mezzanine card model name. Mezzanine 2 Shows the mezzanine card model name. 2-39 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 50 Nameplate power (W) Shows the server blade nameplate power in watts. Weight (kg) Shows the server blade weight. UUID Shows the server blade UUID. 2-40 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 51 LOM Type: Not use LOM (0x00) Use LOM (0x02) Settings tab When a server blade not in SMP configuration is selected, the following items are shown. 2-41 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 52 LP mode. For Basic-mode server blades, "--------" is shown. LP Model Shows an LPAR manager model. Upper bound of Shows the latest version of LPAR manager firmware version available. 2-42 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 53 Optional Physical WWN. MAC type Select MAC address for the LAN adapter on the server blade to use: default physical or optional physical, 2-43 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 54 LPAR manager tab on page 2-72 displays the LP settings. Edit Server Sets the server blade operation: Smart Configure setting at the power Blade settings recovery. 2-44 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 55 The first Start day of the week after Start date • The last Start day of the week before Start date • The last Start day of the week 2-45 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 56 Example: If 192.168.0.1/16 is set, all of IPv4 addresses in network of 192.168.xxx.xxx are allowed to connect. Connection is restricted on the following functions. • Server blade Web console • Remote console 2-46 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 57 If you selected [Disable] for [Use], 0 is set. expiry period If you selected [Enable] for [Use], enter an expiry period (day) in the range from 1 to 365. 2-47 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 58 Cannot change the user account 1 name. Create a string with 1 to 16 characters using alphanumeric, period [.], or underscore [_]. Make sure to start with a number. 2-48 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 59 Same as user account 1. However, for user accounts 2 through 9, you can change the user name. User account User account User account User account User account User account 2-49 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 60 SMASH features. 5985, 5986, 5988, 5989 Table 2-49 IPMI over LAN items Item Description Select Disable or Enable. With this item disabled, BMC will discard RMCP/RMCP+ packets. 2-50 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 61 When security strength is set to high, this item is fixed: disable. You can enable this afterwards. Connection via TLSv1.0 is available regardless of TLS version setting. 2-51 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 62 TLSv1.1 connected. When security strength is set to high, only TLSv1.2 is TLSv1.2 enabled while other versions are fixed: Disable. 2-52 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 63 LDAP server1 Specify LDAP server(s) as IPv4 address in XXX.XXX.XXX.XXX format or FQDN using up to LDAP server2 127 characters. BMC uses LDAP (StartTLS) as 2-53 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 64 CB520H B2 LDAP Ph. value from 0 to 10 as another LDAP server to 2 or later) refer to. If 0 is specified, Referral is disabled. 2-54 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 65 Group DN3 role (Available only with CB 520X and CB520H B2 LDAP Ph. 2 or later) Group DN4 Group DN4 role (Available only with CB 520X and 2-55 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 66 RADIUS server1 Server name Enter the IPv4 address for a RADIUS server in settings the format of XXX.XXX.XXX.XXX or in FQDN (maximum of 127 characters). 2-56 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 67 Refresh button on the upper right to refresh the window. Note: When selecting the primary server blade, you can restart either the primary server blade or all server blades in SMP configuration simultaneously. 2-57 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 68 SMASH supported, put back the port numbers for SMASH (WS- Management) and SMASH (CLP) to the default before the updating. For details, see Hitachi Compute Blade Series SMASH and IPMI User's Guide. • When you turn on or off the server blade using ServerConductor/Blade...
  • Page 69 - For Xeon server blade 540A A1: Not supported - For Xeon server blade 520H B2: Not supported - For Xeon server blade 520H B3 or later: integrated FW version 08-01 or later 2-59 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 70 - For Xeon server blade 520A A1: Not supported - For Xeon server blade 540A A1: Not supported - For Xeon server blade 520H B2: integrated FW version 04-22 or later 2-60 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 71 This phenomenon may occur when A 10Gb LAN pass through module is connected to Brocade VDX switches. This phenomenon can be avoided with any of the following workarounds: 2-61 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 72 This would require proper shutdown of all blades before doing this step. Edit certificate This feature shows, creates, and imports SSL keys and certificates for a server blade BMC. 2-62 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 73 Validity (Not after) Shows an expiration date for the certificate. Issuer Common name Certificate authority (issuer) (CN) Subject Country (C) Shows two alphabetical characters for a country. 2-63 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 74 - ", " . ", " / ", " : ", " = ", and " ? " SHA1 Fingerprint Shows the fingerprint in a certificate, which is a 20-byte hash value by SHA1. 2-64 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 75 Type an e-mail address. Printable ASCII characters are available. DN qualifier Type a DN qualifier using up to 60 characters. The following is available for this item: 2-65 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 76 SSH Host Key Key length Shows the following SSH key algorithm and key length. • RSA (2048 bits) • DSA (1024 bits) Key fingerprint Shows the SSH key fingerprint. 2-66 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 77 Setting items for UEFI setup menu: System Settings > Processors > Hyper-Threading Hardware Select a setting of Hardware Prefetcher, Enable or Disable. Prefetcher Setting items for UEFI setup menu: 2-67 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 78 To set Voltage Level of memory. Set one of the following Voltage Level Auto • Force to 1.50V • Force to 1.35V Setting items for UEFI setup menu: 2-68 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 79 If the new value doesn't show up after editing, wait for a while and then click the Refresh button on the upper right to refresh the window. 2-69 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 80 CNA. This action button is available when the target I/O card is selected. Show Details Shows and changes mezzanine card settings. This action button is available when Hitachi fibre channel adapter is selected. 2-70 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 81 Sets isolation status at HBA port startup. Set it to ON to start the port in isolation. Available values: On and OFF; default value: OFF Shown only for Hitachi 16 Gb fibre channel mezzanine card. Multiple Used along with Connection Type. To expand direct connection PortID configuration, set to Enable.
  • Page 82 Displays the power status of the server blade. status LP condition Displays the LPAR Manager operation status. Condition Normal: Running normally. Starting LPAR feature: LPAR Manager is starting. Error: An error occurred. 2-72 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 83 (Processor groups 0 to 29 can be defined.) Upper bound of Displays the highest version of the supported version LP firmware. 2-73 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 84 Enable: User authentication is required when connecting via Telnet. Disable: User authentication is not required when connecting via Telnet. Note that user authentication is required when connecting by using SSH. 2-74 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 85 Specifies settings for the user authentication functionality. Manage user account Manages user accounts. Show authentication log Displays authentication logs. Recreate SSH host key Recreates the SSH host key. 2-75 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 86: Configuration Information

    If a non-primary server blade is selected, the settings are shown but LPAR manager will not operate with those setting values. Assign firmware to Server Blade (Operating LPAR manager configuration information) 2-76 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 87 Shows the target server blade to assign LPAR manager Assignment firmware. LP firmware Current Shows the LPAR manager version firmware version assigned to the target server blade now. 2-77 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 88 So, in this case, when the Assign firmware to Server Blade (Confirming) dialog box is shown again, the result will be "Unexecuted". 2-78 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 89 Shows the Check result of key dialog box. Cancel Cancels settings and close the Change LP model dialog box. Note: In SMP configuration, change LP model of all server blades in the configuration. 2-79 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 90 Returns to the Change LPAR manager model dialog box. Takes effect the LPAR manager model. Cancel Cancels the setting and closes the Check result of license key dialog box. 2-80 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 91: System Settings

    If they are set in different networks, LPAR manager may fail to start up or a communication error may occur after the startup. When not using Default Gateway, 2-81 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 92 Table 2-83 LP CLI Setting items Item Description User authentication Enable or disable LP CLI user authentication. This item is displayed only if the server blade is powered 2-82 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 93 Specify the TCP port to be connected to a virtual COM console via port Telnet or SSH. Table 2-86 Action button at the bottom Item Description Confirm Shows the Confirming dialog box. 2-83 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 94: Authentication Settings

    Table 2-88 Action button at the bottom Item Description Confirm Shows the Confirming dialog box. Cancel Cancels the setting and returns to the LP Setting dialog box. 2-84 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 95: User Account Management

    Removes the selected account. Edit Changes the password of the selected account. Close Closes the Manage user account dialog box, and returns you to the LPAR Manager tab. 2-85 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 96 LP CLI LPAR No. If a virtual COM console is used, the connected LPAR number is displayed. Port Displays the port number of the connected client. 2-86 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 97 Creates an SSH host key. Cancel Stops creating an SSh host key, and returns you to the LPAR Manager tab. LPAR tab • LP mode: Disabled; server blade: powered off 2-87 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 98 Table 2-94 Items when the server blade is powered off in Basic mode Item Description LP Settings Shows the LPAR manager Settings dialog box. • LP mode: Disabled; server blade: powered on 2-88 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 99 • LP mode: Enabled; server blade: powered off 2-89 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 100 LP mode: Enabled; server blade: powered on Table 2-96 Items when the server blade is powered on in LP mode: Enabled Item Description Shows LPAR number. 2-90 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 101 Shows USB port setting dialog to edit USB device assignment. Scheduling mode [Management module firmware version A0240 or later] Scheduling mode settings. Deactivate Deactivate an LPAR. Reactivate Reactivates an LPAR. 2-91 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 102 Collect LP dump log Only for management module firmware version A0145 or later, LP dump in operation is collected and downloaded. Tip: See "USB/KVM" in Chapter 1, Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide for USB assignment and status transition.
  • Page 103 Firmware Version Shows a version of the LPAR manager firmware assigned. Bank Shows a bank number assigned. LP License LP model Shows an LPAR manager model. 2-93 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 104: Language

    Server Blade CLI Setting Shows CLI IP address settings. Server Blade IP address Shows the BSM IP address. BSM Interface Alert port Shows the BSM alert port. Setting 2-94 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 105 Edit settings Change LPAR manager settings. Shows the LP Settings (Editing) dialog box. Save settings Save LPAR manager configuration. Close Close the LP Setting dialog box. 2-95 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 106 CLI IP address 1 to 8 CLI Setting Server Blade BSM 1 to 4 IP address Alert port Interface Setting Y: Available; N/A: Not available; -: Out of target 2-96 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 107 If a non-primary server blade is selected, the settings are shown but LPAR manager will not operate with those setting values. • Assign firmware to Server Blade (Operating LPAR manager configuration information) 2-97 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 108 Table 2-104 Items in Assign firmware to Server Blade (Confirming) Item Description LP fimware Server Blade No. Shows the target server blade Assignment to assign LPAR manager firmware. 2-98 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 109 Assign firmware to Server Blade (Operating LPAR manager configuration information) dialog box, the result whether LPAR manager configuration information is backed up/restored is cleared. So, in this 2-99 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 110 Cancels settings and close the Change LP model dialog box. Note: In SMP configuration, change LP model of all server blades in the configuration. • Check result of license key 2-100 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 111 Returns to the Change LPAR manager model dialog box. Takes effect the LPAR manager model. Cancel Cancels the setting and closes the Check result of license key dialog box. • LP Settings (Editing) 2-101 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 112 Sets Logical Partitioning disable. button IP Address text box Sets IPv4 address used by LPAR manager. The format of IPv4 is (xxx.xxx.xxx.xxx). (xxx: a figure between 0 and 255) 2-102 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 113 Sets LP CLI address 1 to 8. Option Note: The items which are not explained above are shown. The items are hidden when the items are not set. 2-103 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 114 Time Zone Shows your time zone. CLI IP address 1 – 8 Shows LP CLI address 1 to 8. Note: Shows LPAR manager initial setting information. 2-104 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 115 World Wide Node Name, World Wide Port Name, and Enable or Disable for boot function. [Management module firmware version A0205 or later] 2-105 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 116 Modifies LPAR settings. This button is available when the LPAR is deactivated: LPAR state is DEACT. Close Closes the LPAR Information dialog box. • Modify LPAR 2-106 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 117 Shows assigned NICs. [Management module firmware version A0205 or later] Shows assigned USBs. [Management module firmware version A0205 or later] Shows items other than those above. 2-107 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 118 Shows controller number. Scheduling mode [Management module firmware version A0240 or later] Shows scheduling mode. Port Shows HBA ports on the server blade. 2-108 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 119 Saves HBA settings and closes the Set HBA port dialog box. Cancel Cancels settings and returns to the Modify LPAR dialog box. • Set NIC port 2-109 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 120 Shows a NIC controller number on the server blade. Scheduling mode [Management module firmware version A0240 or later] Shows a NIC scheduling mode on the server blade. 2-110 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 121 Shows USB ports on the server blade. When multiple USB devices are available, the following items are shown. USB/KVM: Port to connect to the remote console 2-111 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 122 Shows the number of logical processors before assigned to the LPAR and a scheduling mode of the logical processor: shared or dedicated. Memory Shows a memory amount assigned to the LPAR. 2-112 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 123 Return to the Modify LPAR dialog box. Save the settings and closes the Modify LPAR (confirmation) dialog box. Cancel Cancels settings and closes the Modify LPAR (confirmation) dialog box. • Add LPAR 2-113 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 124 Shows assigned NICs. [Management module firmware version A0205 or later] Shows assigned USB. [Management module firmware version A0205 or later] Shows setting items other than shown above. 2-114 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 125 [Management module firmware version A0205 or later] Shows the number of a server blade in which the card is installed and the card type in SMP configuration. 2-115 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 126 Cancels settings and closes the Add LPAR (confirmation) dialog box. • Boot order settings [Management module firmware version A0125 or later] With server blade model CB 520X, this setting is not available. 2-116 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 127 ---- -: The information cannot be taken due to the dedicated mode. (HBA, PXE) Available: Operate normally.(HBA) ConfigCheck: Cannot be used due to a configuration problem. (HBA) 2-117 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 128 (When selecting the HBA tab) Add to boot Adds the selected device to the boot order. order button Notes: Shows LPAR boot order. 2-118 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 129 If you need to change them, change to the dedicated mode temporarily. • HBA boot settings (Confirm) [Management module firmware version A0125 or later] With server blade model CB 520X, this setting is not available. 2-119 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 130 Saves the new boot order settings and closes the HBA boot settings. Cancel Cancels the new settings and go back to the LPAR Information dialog box. 2-120 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 131 Switch modules window shows operation status of all switch modules. You can perform basic operations, including powering or off, to all or selected multiple server blades. 2-121 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 132 Power Shows a power supply state on the Web console among the following states: ON: Powered on OFF: Powered off. -----: No switch module is installed. 2-122 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 133: Switch Module

    Switch module window provides a selected switch module operation status, hardware information. You can perform its operations, including basic settings for Hitachi 1 Gb LAN switch module (20 ports and 40 ports), Hitachi 1/10 Gb LAN switch module, and starting Brocade 8 Gb fibre channel switch module and Brocade 16 Gb/sec fibre channel switch module Web console.
  • Page 134 Clears the switch module authentication information that is authentication displayed. Uses the default account (operator, no password) to settings authenticate after clearing the switch module authentication information. 2-124 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 135 IP Address Shows the IP address for service personnel during maintenance. Connecting to the switch module via LAN 2-125 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 136 Full: Performs all diagnostics. It takes about 15 minutes until the switch module has completely started up. Settings tab For Hitachi 1 Gb LAN switch module (20 ports and 40 ports); Hitachi 1/10 Gb LAN switch module: 2-126 Operating the Web Console...
  • Page 137 Terminal Console Edits the number of terminal consoles that can log in at a time. Save Settings Saves the new settings in the startup configuration file. 2-127 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 138 You cannot set over 945 characters. • Only for Hitachi 1Gb LAN switch module (40 ports), you can set over 945 characters. However, you cannot set through the Web console, set using the switch module that is connected directly.
  • Page 139 Management modules This window shows the operation status of management modules. You can perform basic operations, including powering or off, to all or selected multiple management modules. 2-129 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 140 This item is not shown when a single management module is installed. Backup Settings Create a backup file for the management module configuration and download it. 2-130 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 141 Status Shows an operation state of the management module among the following states. Normal: In normal state. Booting: In initialization state. Shutting down: In shutdown state. 2-131 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 142: Management Module

    Management module This window shows the operation status of a selected management module, hardware information. You can perform its operations. 2-132 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 143 Shutdown Shuts down the management module currently shown. Shutting down the active management module disconnects the Web console. Then. re-login is required for operation. 2-133 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 144 The management module has no redundancy. -----: No management module is installed. Maintenance ON/OFF ON: Set in maintenance mode. mode OFF: Not set in maintenance mode. 2-134 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 145 Turns on the LID (Identification LED) of the management module currently shown. LID OFF Turns off the LID (Identification LED) of the management module currently shown. 2-135 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 146: Fan Modules

    Table 2-153 Action button at the bottom Item Description Show FRU/Sensor Shows FRU and sensor values of the management module. Fan modules This panel shows fan module information. 2-136 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 147 Failed: In failed state. Check the failed content in the event list. -----: No fan module is installed. Fan 0 [rpm] Shows the rpm of Fan 0. Fan 1 [rpm] Shows the rpm of Fan 1. 2-137 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 148: Power Supply Modules

    Warning: In warning state. Check the warning in the System Event Log. Failed: In failed state. Check the failed content in the System Event Log. -----: No power supply module is installed. 2-138 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 149 Shows an operation state of the power supply module among the following states. Normal: In normal state. Warning: In warning state. Check the warning in the event list. 2-139 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 150 Table 2-158 Action button at the bottom Item Description Show FRU/Sensor Shows FRU and sensor values of the power supply module. Systems This section describes items shown for Systems. 2-140 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 151: Management Lan

    Default Gateway setting to the LAN switch module, check "Not apply this Default Gateway setting to the LAN switch module" shown in Edit IP Address window. 2-141 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 152 • When a value other than 0.0.0.0 is set as the default gateway of Hitachi 1 Gb LAN switch module (20-port, 40-port) and Hitachi 1/10 Gb LAN switch module, the setting value will be added after all default gateways without interface specified are deleted.
  • Page 153 If static addressing is disabled, ----- is displayed. Default Gateway Table 2-162 Action button at the bottom Item Description Edit Edits the IP address (IPv6) settings of the management interface. 2-143 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 154 DNS servers for IPv6 addresses are preferentially used based on the priority setting. If three servers are used, an access attempt will not be made to DNS servers. 2-144 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 155 Module names are abbreviated as follows: MM: management module SVn: server blade n SWn: switch module n Tip: See "Network" Hitachi Compute Blade 500 Series Management Module Setup Guide for VLAN. 2-145 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 156 Server Blade 0 to 7 Shows MAC addresses for server blade BMCs. Maintenance LAN This window shows the maintenance LAN interface settings for management modules. Those settings cannot be changed. 2-146 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 157 Network Subnet This item is not available. Mask Gateway Internal LAN Internal networks used for the system unit is set on this window. 2-147 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 158 Fault tolerance in the management LAN interface can be set on this window. You can enable or disable the link fault tolerance and set the monitoring time. 2-148 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 159 Standby: This port is standby and available for switching to active when the active port is linked down. Down: Linked down between this port and the corresponding one. 2-149 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 160 (sec), the port will be recovered to the management module. Table 2-172 Action button at the bottom Item Description Edit Edits the management interface settings. 2-150 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 161 This window shows WWNs: WWN (Default Physical WWN) unique to hardware; Optional Physical WWN; Virtual WWN used by a mezzanine card installed in a server blade. You can set them on the window. 2-151 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 162 Default Physical WWN is not shown. Virtual WWN Shows Virtual WWNs used in LPAR manager. In the case that a server blade is not installed, Virtual WWN is not shown. 2-152 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 163 If the same Optional Physical WWN exists in the system unit, shown on the head of it. Modify the Optional Physical WWN to be unique using the Edit button. 2-153 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 164 Table heading Shows the server blade number and mezzanine card number and name. Port Shows port numbers. World Wide Port Name Shows World Wide Port Names. 2-154 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 165 Table 2-180 Action buttons Item Description Export to CSV Outputs the original virtual WWN list to a CSV file. Close Closes the original Virtual WWN dialog box. 2-155 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 166 Optional Physical MAC addresses assigned to the server blade are shown regardless of the server blade N+M settings, the type of MAC address, and the number of mezzanine cards installed. 2-156 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 167 If the same Optional Physical MAC address exists in the system unit, is shown on the head of it. Modify the Optional Physical MAC to be unique using the Edit button. 2-157 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 168 Table heading Shows the server blade number and mezzanine card number and name. Controller Shows the number of a network controller installed in the mezzanine card. Port Shows the port number. 2-158 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 169 Table 2-187 Action buttons at the bottom Item Description Export to CSV Outputs the original virtual MAC list to a CSV file. Close Closes the original Virtual MAC list dialog box. 2-159 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 170: Power Management

    This window manages power to the entire system unit and each module, showing the status of power supply and consumption, capping the power consumption, and setting the power supply module redundancy. See "Power saving function" Hitachi Compute Blade 500 Series Management Module Setup Guide for power management. Power summary...
  • Page 171 (EPC) control) power capping value for protecting the equipment. Power rating of chassis Shows the total rated values of modules in the server chassis. 2-161 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 172 (DC) consumption modules in the server chassis. Average power Shows the average consumed by modules in consumption the server chassis for the last 3minutes. (3min). 2-162 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 173 200VAC – 240VAC: 15A – 100A (default value: 24A) Number of PDU Sets the number of PDUs: 0/1/2 With N+N, default value is 2. With N+1, default value is 1. 2-163 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 174 Shows the chassis rated power. Present power Shows the power currently consumed. consumption Average power Shows the average power consumption for the last 3 minutes. consumption 2-164 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 175 Sets the power capping (APC/EPC) to the selected server blade. If DCMI mode is enabled, only EPC can be set. Note: Do not disable Emergency power control (EPC). 2-165 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 176 Table 2-193 Switch module items Item Description Switch module Shows the number of a switch module. Power Shows the power state. Nameplate power Shows the nameplate power. 2-166 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 177 Table 2-194 Management module items Item Description Management module Shows the number of a management module. Power Shows the power state. Nameplate power Shows the nameplate power. 2-167 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 178 Sets the AC recovery setting of a power supply module. HA monitor To use the HA monitor, specify the settings for linking to the HA monitor in this window. 2-168 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 179 N+M Cold standby Shows whether to link with N+M cold standby to use the HA monitor. Enable: Performs a system failover in the N+M cold standby configuration. 2-169 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 180 This window shows server blade firmware and LPAR manager firmware versions. You can update them on this window. Multiple server blade firmware versions can be updated at a time. See Hitachi Compute Blade 500 Series Management Module Setup Guide for details. Server blade tab...
  • Page 181 In SMP configuration, select the primary server blade to update firmware, which updates the firmware on all server blades in the configuration simultaneously. You need not to select non-primary server blades. 2-171 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 182 "-----"(not assigned)" is selected for, this button is available. Tip: The server blade to which a LPAR manager firmware bank is assigned can be confirmed in Server Blade tab. 2-172 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 183 LP license This window shows the LPAR manager license for server blades. See Hitachi Compute Blade 500 Series Management Module Setup Guide for details. Table 2-203 LP license items Item Description Server Blade Shows the number of a server blade.
  • Page 184 Cancel Cancels the settings and closes the Change LP model dialog box. Check result of license key This window shows the new LPAR manager model information. 2-174 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 185 CBTP CBTP. Compute Blade Test Program, is a test program to run after hardware is changed for maintenance. The following window shows CBTP for server blades. 2-175 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 186 Shows the ISO image name that has been mounted. image Latest Date Shows the latest date when CBTP was executed. and Time Latest result Shows the latest CBTP result. 2-176 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 187 Opens a dialog box to confirm to mount the ISO image. Cancel Cancels mounting the ISO image and closes the dialog box. • Show result history 2-177 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 188 Description Show detail Shows detailed result of CBTP execution. Show hardware configuration Shows hardware configuration in CBTP execution. Close Closes the dialog box. • Download log 2-178 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 189 File size Shows the log file size. Table 2-216 Action buttons at the bottom Item Description Starts downloading the log file. Cancel Cancels downloading the log file. 2-179 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 190 Click Refresh to update the window after uploading the ISO image. Security strength The following tab allows you to set security strength to management modules and server blades. See Security strength in Hitachi Compute Blade 500 Series Management Module Setup Guide for details. 2-180...
  • Page 191 Failed initialization: Not obtained the state due to failed initialization. Table 2-219 Action button at the bottom Item Description Edit Edits a setting value of Security strength. 2-181 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 192 Edits a setting value of TLS/SSL version. Alerts This section describes the alerts tab. System event log This window shows system event logs (SEL). Warning and Failed events may provide their details. 2-182 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 193 : An event that needs to caution the user occurred, such as an error in communication and in configuration. : A module has an error but can be kept in operation. Check details of the warning and remove the problem. 2-183 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 194 This window shows Optional Physical WWN change log history. Optional Physical WWNs are switched at N+M cold standby and changed at the return to the original state. 2-184 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 195 This window shows Optional Physical MAC change log history. Optional Physical MACs are switched at N+M cold standby and changed at the return to the original state. 2-185 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 196 Shows either Console or BSM0 to BSM3 for the source that requested the change. Operation logs This window provides operation logs to management modules and server blades (BMC), which are available for download. 2-186 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 197 Description Download Select a management module or server blade BMC 0 to BMC 7 to download the operation logs. Tip: See "Log" Hitachi Compute Blade 500 Series Management Module Setup Guide for Operation logs. MAR logs This window shows maintenance action report (MAR) logs that cause a failure to be reported.
  • Page 198 Environment log This window shows the lowest, highest, and average temperature of intake and exhaust air per day. The history can be downloaded from this window. 2-188 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 199: Administration

    Description Download Downloads the daily history of the lowest and highest temperature for the past 700 days. Administration This section describes items on the administration tab. 2-189 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 200: Users And Roles

    Shows whether or not the account is available. If the account is invalid, you cannot log in with the account. The account can be unavailable temporarily with Disable without deleting it. 2-190 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 201 Create Adds, deletes, and edits accounts. See Account information on page 2-191 details. Delete Edit Account information Create account The following window and table show items for creating and editing user accounts. 2-191 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 202 Shows the CLI console automatic timeout. Session timeout ranges from 1 Time (min) to 1440 minutes. With the Web console, the session is automatically disconnected in 30 minutes regardless of this setting. 2-192 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 203: Password Policy

    Table 2-236 Password Policy items Item Description Management of Displays whether management of password expiration dates is password enabled. expiration date Enable: Password expiration dates are managed. 2-193 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 204 Role The following window and tables show items for Role. 2-194 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 205 When RO is marked with X, setting change and operation are not available for the management network regardless of this item with X. 2-195 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 206 Web console. LDAP This feature sets connection to an LDAP (Lightweight Directory Access Protocol) server. You can manage account collectively by connecting to an LDAP server. 2-196 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 207 Specifies an attribute for containing accounts allowed to log in. For Active Directory, "member", a common attribute name, is used for the user account list. 2-197 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 208 Edits LDAP server settings. Directory search Edits directory search settings. Group authentication Edits group authentication settings. Sessions This feature shows all logged-in users. You can forcibly disconnect unnecessary connections. 2-198 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 209 Date and time This window controls the management module time, including a local time, time zone, Summer time, and NTP server settings. 2-199 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 210 DST Status Shows either in the daylight saving time or in the standard time at present. Table 2-245 Action button at the bottom Item Description Edit Changes the local time in the management module. 2-200 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 211 Last day on or before the specified date is Sunday, Month is 3, and Date is 24, it is the first Sunday on or before 24th of March, the second Sunday from the end of the month. 2-201 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 212 Connected: Obtaining the time is possible. • Synchronization: The time is being synchronized. • Not Synchronization: The time is not synchronized because a large time difference exists. 2-202 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 213 Shows either English or Japanese is used for the unit console, alerts, Language and e-mail notification. Each user can specify a language. See Users and roles on page 2-190 for details. 2-203 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 214: Services

    Table 2-252 Action combo box on the upper right Item Description SSH Host Key Settings Shows and recreates SSH host key information including key length and fingerprint. 2-204 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 215 Net mask prefix length) about the network from which connections are allowed. Table 2-254 Action button at the bottom Item Description Edit Edits Telnet service settings. 2-205 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 216 Net mask prefix length) about the network from which connections are allowed. Table 2-256 Action button at the bottom Item Description Edit Edits FTP service settings. 2-206 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 217 IP address If access control is set to Allowed (With restrictions), network this item displays information (network address and Net mask prefix length) about the network from which connections are allowed. 2-207 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 218 Displays IPv6 access control settings for connections to the management module via HTTP. The following settings are available: Allowed (No restrictions), Allowed (With restrictions), and Prohibited. 2-208 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 219 Then, change the corresponding port number on their side. IPv4 Access control Displays IPv4 access control settings for connections to the management module via HTTPS. The following 2-209 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 220: Snmp

    Table 2-262 Action button at the bottom Item Description Edit Edits HTTPS service settings. SNMP This feature shows and edits connection to SNMP Agent and SNMP Manager. SNMP Agent tab 2-210 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 221 Shows an Engine ID used by the agent. This item is automatically created from a character string for creating the Engine ID. Table 2-265 Action button at the bottom Item Description Edit Edits SNMP agent settings. 2-211 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 222 Table 2-267 Action button at the bottom Item Description Adds SNMP Managers to connect. Remove Removes a selected SNMP manager. Edit Edits a selected SNMP manager. 2-212 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 223 Available with SNMP Manager version: v3, and Access type: password AuthonoPriv or AuthPriv: Type a password for the SNMP Manager authentication using from 8 up to 64 alphanumeric characters and symbols. 2-213 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 224: E-Mail Notification

    Shows the MIB file version. Table 2-270 Action button at the bottom Item Description Download MIB file Downloads the MIB file. E-Mail Notification This feature edits E-Mail Notification. 2-214 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 225 Host Shows the host name. Set FQDN with up to 64 name(FQDN) characters. Comment Shows the set comment appropriately. Set one with up to 32 characters. 2-215 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 226 When SMTP is enabled, make sure to set the account and password. Table 2-273 Action button at the bottom Item Description Edit Edits the E-Mail Notification settings. 2-216 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 227: Sc/Bsm

    Removes the E-Mail address of sender. Edit Edits the E-Mail address of sender. SC/BSM You can interface with SC (ServerConductor)/BSM (Blade Server Manager) on this window. 2-217 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 228 Only if using a port number other than the default value: 20079, change the port number. Alert Level Select one or more from three levels shown below. All: Sends all level alerts including Failed, Warning, and Information. 2-218 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 229: Hcsm

    Removes registered SC/BSM servers that you select. Edit Server Setting Edits selected SC/BSM server connection settings. HCSM This feature sets connection to HCSM (Hitachi Compute Server Manager) and forcible disconnection from HCSM. 2-219 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 230 2-221 is available. Account Shows the user for HCSM. Table 2-281 Action button at the bottom Item Description Edit Edits HCSM service settings. 2-220 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 231 Shows the alert retry duration from 4 to 15 minutes in case that an duration [min] alert cannot be notified to SC/BSM due to temporary failure in the network. 2-221 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 232: Hi-Track

    Access control Shows Enable or Disable Access control to the management module due to the IP address. With Enable, only access from the Hi-Track address shown in Hi-Track Servers tab on page 2-223 is available. 2-222 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 233 Table 2-287 Action button at the bottom Item Description Adds Hi-Track to connect. Edit Edits settings for connection to Hi-Track. Delete Deletes the register of a selected Hi-Track. 2-223 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 234: Certificate

    Alphanumeric characters, " ", " ' " , " ( ", " ) ", " + ", " , ", " - ", " . ", " / ", " : ", " = ", and " ? " 2-224 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 235 Files in PEM (Privacy enhanced mail) can be imported. For around 15 seconds at the maximum after the import is completed, connection via HTTP or HTTPS is not available. 2-225 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 236: Syslog Transfer

    Syslog transfer This feature allows you to transfer system logs to the syslog server. See Syslog transfer in Hitachi Compute Blade 500 Series Management Module Setup Guide for details. Table 2-290 Syslog transfer items Item Description Syslog transmitting function Shows a setting of Syslog transfer: Enable or Disable.
  • Page 237 ! " # $ & ' ( ) * + , - . / : ; < = > ? @ [ ] ^ _ ` { | } ~ Table 2-293 Action button at the bottom Item Description Edit Edits the login banner settings. 2-227 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 238 2-228 Operating the Web Console Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 239 Hitachi Compute Blade 500 Series Web Console User's Guide...
  • Page 240 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0)1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com MK-91CB500015-11...

Table of Contents