(a) moduleStatusBlade group (2/34)
Object
No
identifier
8
bladeStatus
.1.3.6.1.4.1.11
SensorCapa
6.5.39.3.2.1.1.
cityTemperat
5
ure
9
bladeStatus
.1.3.6.1.4.1.11
CurrentCurre
6.5.39.3.2.1.1.
ncy
6
10
bladeStatus
.1.3.6.1.4.1.11
Current
6.5.39.3.2.1.1.
Power
7
11
bladeStatusF
.1.3.6.1.4.1.11
anRpm
6.5.39.3.2.1.1.
8
12
bladeStatusF
.1.3.6.1.4.1.11
anAirVolume
6.5.39.3.2.1.1.
9
13
bladeStatusI
.1.3.6.1.4.1.11
ntakeTemp
6.5.39.3.2.1.1.
10
14
bladeVoltage
.1.3.6.1.4.1.11
Table
6.5.39.3.2.2
15
bladeVoltage
.1.3.6.1.4.1.11
Entry
6.5.39.3.2.2.1
16
bladeVoltInd
.1.3.6.1.4.1.11
ex
6.5.39.3.2.2.1.
1
17
bladeVoltSe
.1.3.6.1.4.1.11
nsor1Name
6.5.39.3.2.2.1.
2
(*2)
A value that the server blade obtains from a voltage and temperature sensor is shown.
"0" is shown if no server blade or no sensor is installed.
(*3)
The reply is "normal" if no server blade is installed or the server blade power is off.
(*4)
"Not install" is shown if no server blade is installed; "Not support" is shown if a server
blade is installed without any sensor; "Cannot get data" is shown if the data cannot be
obtained.
(*5)
The response is "0" if no server blade or no sensor is installed. Obtain the MIB object of
the next OID, and determine whether or not the replied value is valid.
(*6)
"invalid" is shown if no server blade or no sensor is installed; "unknown" is shown if no
information can be obtained".
(*7)
With SMP configuration, when the primary blade location in a partition is specified, the
values of the entire partition are displayed; when a blade location other than the primary
one is specified, "0" is displayed.
OID
Syntax
Integer32
Integer32
Integer32
Integer32
Integer32
INTEGER
Not-
Accessible
Not-
Accessible
Integer32
Display
String
1630
Acces
Description
s
RO
Shows the maximum number of
temperature sensors for a server
blade. (*2)
RO
Shows the current being
consumed at present by the
server blade installed in the slot
shown in #5. This is shown as 1
for 0.1A. (*2)(*7)
RO
Shows the power being
consumed at present by the
server blade installed in the slot
shown in #5. This is shown as 1
for 1W. (*2)(*7)
RO
Shows the Rpm number of the
fan in the server blade. This is
shown as "0".
RO
Shows the air volume provided
by the fan in the server blade.
This is shown as "0".
RO
Shows the inlet air temperature
status to the server blade
installed in the slot shown in #5.
(*3)
1: normal
2: higher-warning
3: error-warning
4: lower-warning
NA
Shows the table of information
on the voltage sensor with the
server blade.
NA
Shows the table entry of
information on the voltage
sensor with the server blade.
RO
Shows the index value ranging
from 1 to chassisCapacityBalde
to identify the table entry.
RO
Shows the voltage sensor name
for the server blade in the slot
shown in #5. (*4)