Make sure to apply the same LPAR manager firmware version with the active partition
to the standby partition. If you apply different LPAR manager firmware versions to the
active and standby partition, N+M failover may fail. If LPAR manager firmware of all
server blades cannot be updated at a time in the system with N+M cold standby,
discrepancy between LPAR manager firmware versions is allowed as long as the LPAR
manager firmware version of the standby server blade is later than that of the active
one.
Select a proper PCI error handling mode for the system configuration. If not, the N+M
failover may fail. See
 Partition configuration information to be taken over by the N+M
cold standby
(1) Partition in Basic mode
During N+M failover in the Basic mode, the following information is taken over by the
standby partition from the active partition.
Item
WWN
MAC address
Server blade setting
(EFI/BMC)
HBA BIOS setting for Fibre-
channel board
Emulex 10 Gb CNA setting Preboot eXecution Environment (PXE) Boot
NOTICE
PCI error handling mode
World Wide Node Name
World Wide Port Name
Media Access Control address
Whether to use Network Time Protocol (NTP)
server or not.
Timezone setting , real-time clock (RTC) (basic
input/output system (BIOS) time)
Type of OS (use or not use LPAR manager)
Schedule data
Remote KVM mouse mode:
relative coordinate or absolute coordinate
Displayed language setting
EFI setting
Boot order
HBA BIOS setting: Enable or Disable
Boot priority setting: Enable or Disable
Boot target WWN
logical unit number
Boot target
Support
PXE VLAN Support/PXE VLAN ID/PXE VLAN
Priority
Admin Logical Link
(with MultiChannel Support : Enabled)