1.2
Checking the OS serial port settings
The OS console uses the server blade's COM1 port.
Sample setup with a server blade running Windows
Make sure the OS's COM1 port settings are as follows:
Port: COM1
Baud rate: 115200
Data bits: 8
Parity bits: None
Stop bits: 1
Flow control: None
Recommended terminal type: VT100
The OS console cannot be used as a Windows Special
Administration Console (SAC).
Sample setup with a server blade running Linux 5
This example is for Red Hat Linux.
1
/boot/grub/grub.conf setting
At the end of each kernel line, enter the console parameters to be passed to the
kernel.
console=tty0 console=ttyS0,115200
2
/etc/inittab setting
(1) To the last line, append "co:2345:respawn:/sbin/agetty 115200 ttyS0 vt100".
(2) Execute "init q(telinit -q)".
3
/etc/sysconfig /kudzu setting
Change to "SAFE=yes".
4
/etc/securetty setting
Add "ttyS0".