When configuring N+M cold standby with Emulex 10 Gb CNA, make sure to
configure the following settings for the Emulex 10 Gb CAN on active and
standby partitions.
Set the same Multi Channel Support setting to the active and standby
partitions.
Set the same Personality setting to the active and standby partitions.
Set a unique iSCSI Initiator IP Address.
Set Connected as Connection Status for iSCSI Target.
The number of sessions for iSCSI Target is up to four sessions per port.
iSCSI interface and FCoE interface cannot be mixed on the same partition.
See the 10Gb Converged Network Production Instruction Manual for details
about Emulex 10 Gb CNA.
If the prerequisite conditions described above are not
satisfied when Emulex 10 Gb CNA is installed on the
active and standby partitions, N+M cold standby does
not work properly.
To take over settings Emulex 10 Gb CNA with N+M
cold standby, the following conditions need to be
satisfied.
Item
Server blade
Management module firmware
To take over settings Emulex 10 Gb CNA (iSCSI for
Personality) with N+M cold standby, the following
conditions need to be satisfied.
Item
Server blade
Management module firmware
Condition
Standard server blade: X55S3
BMC firmware: 05-17 or later, or 07-01 or later
EFI firmware: 09-40/10-40 or later
High-performance server blade: X57A2
BMC firmware: 04-68 or later
EFI firmware: 07-40/08-40 or later
A0330 or later
Condition
Standard server blade: X55S3
BMC firmware: 05-50 or later, or 07-01 or later
EFI firmware: 09-43/10-43 or later
High-performance server balde: X57A2
BMC firmware: 04-71 or later
EFI firmware: 07-43/08-43 or later
A0345 or later