Hitachi Compute Blade 2000 User Manual page 1703

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(a) moduleStatusBlade group (19/34)
Object
No
identifier
138
bladeTemper
.1.3.6.1.4.1.11
atureEntry
6.5.39.3.2.3.1
139
bladeTempIn
.1.3.6.1.4.1.11
dex
6.5.39.3.2.3.1.
1
140
bladeTempS
.1.3.6.1.4.1.11
ensor1Name
6.5.39.3.2.3.1.
2
141
bladeTempS
.1.3.6.1.4.1.11
ensor1Value
6.5.39.3.2.3.1.
3
142
bladeTempS
.1.3.6.1.4.1.11
ensor1Valid
6.5.39.3.2.3.1.
4
143
bladeTempS
.1.3.6.1.4.1.11
ensor2Name
6.5.39.3.2.3.1.
5
144
bladeTempS
.1.3.6.1.4.1.11
ensor2Value
6.5.39.3.2.3.1.
6
145
bladeTempS
.1.3.6.1.4.1.11
ensor2Valid
6.5.39.3.2.3.1.
7
(*1)
The reply is "unknown", if no server blade is installed or the status cannot be obtained.
(*2)
A value that the server blade obtains from a voltage and temperature sensor is shown.
"0" is shown if no server blade or no sensor is installed.
(*3)
The reply is "normal" if no server blade is installed or the server blade power is off.
(*4)
"Not install" is shown if no server blade is installed; "Not support" is shown if a server
blade is installed without any sensor; "Cannot get data" is shown if the data cannot be
obtained.
(*5)
The response is "0" if no server blade or no sensor is installed. Obtain the MIB object of
the next OID, and determine whether or not the replied value is valid.
(*6)
"invalid" is shown if no server blade or no sensor is installed; "unknown" is shown if no
information can be obtained".
OID
Syntax
Not-
Accessible
Integer32
Display
String
Integer32
INTEGER
Display
String
Integer32
INTEGER
1652
Access
Description
NA
Shows the table entry
describing the information on
the server blade temperature
sensor.
RO
Shows the index value ranging
from 1 to chassisCapacityBlade
to identify the table entry.
RO
Shows the temperature sensor
name for the server blade in
the slot shown in #5. (*4)
RO
Shows the temperature value
of the server blade in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1°C.
The actual value is one-tenth of
the response value.
RO
Shows the temperature value
validity of the server blade in
the slot shown in #5. One of the
following values is shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the temperature sensor
name for the server blade in
the slot shown in #5. (*4)
RO
Shows the temperature value
of the server blade in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1°C.
The actual value is one-tenth of
the response value.
RO
Shows the temperature value
validity of the server blade in
the slot shown in #5. One of the
following values is shown. (*6)
1: invalid
2: valid
3: unknown

Advertisement

Table of Contents
loading

Table of Contents