(b) moduleStatusMm group (2/7)
Object
No
identifier
8
mmStatusRun
ningStatus
9
mmStatusSen
sorCapacityVo
ltage
10
mmStatusSen
sorCapacityTe
mperature
11
mmVoltageTa
ble
12
mmVoltageEnt
ry
13
mmVoltIndex
14
mmVoltSensor
1Name
15
mmVoltSensor
1Value
(*1)
"unknown" is shown in the process of setting redundancy, or when no management
module is installed or the status cannot be obtained.
(*2)
"unknown" is shown when no management module is installed or the status cannot be
obtained. "power-off" is shown after executing SDN in the process of setting
redundancy.
(*3)
"0" is shown as the number of sensor when no management module is installed.
(*4)
"Not install" is shown if no management module is installed or redundancy setting is on
the process; "Cannot get data" is shown if the data cannot be obtained.
(*5)
"0" is shown if no management module is installed or redundancy setting is on the
process, if the data cannot be obtained, or if no sensor exists.
(*6)
"invalid" is shown if no management module is installed or redundancy setting is on the
process; "unknown" is shown if no data is obtained".
OID
Syntax
.1.3.6.1.4.1.1
INTEGER
16.5.39.3.3.1
.1.5
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.1
.1.6
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.1
.1.7
.1.3.6.1.4.1.1
Not-
16.5.39.3.3.2
Accessible
.1.3.6.1.4.1.1
Not-
16.5.39.3.3.2
Accessible
.1
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.2
.1.1
.1.3.6.1.4.1.1
Display
16.5.39.3.3.2
String
.1.2
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.2
.1.3
1669
Acces
Description
s
RO
Shows the running status of the
management module in the slot
shown in #5. One of the
following messages is shown.
(*2)
1: active
2: standby
3: unknown
RO
Shows the max number of
voltage sensors for the
management module in the slot
shown in #5. (*3)
RO
Shows the max number of
temperature sensors for the
management module in the slot
shown in #5. (*3)
NA
Shows the table of information
on the voltage sensor for the
management module.
NA
Shows the table entry describing
the information on the voltage
sensor for the management
module.
RO
Shows the index value ranging
from 1 to chassisCapacityMm to
identify the table entry.
RO
Shows the voltage sensor name
for the management module in
the slot shown in #5. (*4)
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1 V.
The actual value is one-tenth of
the response value.