 Fan module specifications per module
Item
Rated voltage (permissible variation)
Rated current
Rated input power
Number of installed fan modules
Maximum wind amount
Maximum static pressure (Pa: inchiH2O)
Sound pressure level (dB[A])
Permissible humidity variation (°C)
Rotation control method
Unplugging/plugging method
Protection method
Redundancy method
Indicator
Humidity sensor
Outside dimension (W x D x H: mm)
Mass
 AC power input module specifications per module
Item
AC cable
AC plug
Rated voltage
Rated current
Outside dimension (W x D x H: mm)
Mass
Specification
12 (10.8 to 13.2) V
12 A
144 W
3
4.5 m3/min: 159 CFM
1600 Pa: inchiH2O
74.3 dB[A]
5 to 70°C
Pulse width modulation (PWM) control via
I2CBus
HotSwap
Breaks the over current with a fuse.
HotSwap Controller OCP function
N+1
Active (green); Failure (orange)
Installed on the control board.
83 x 237 x 85.8 (except Backplane connector)
1.44 kg
Specification
2 input connectors
4.5 m x 2 cables
NEMA L6-30P(GVX-BE2ACM1X1)
IEC60309-32(GVX-BE2ACM1X2)
AC200 V to 240 V
24 A/AC cable
209 x 62.7 x 42.5 (except connector)
2.56 kg
20
1 input connector
4.5 m x 1 cable
24 A
1.43 kg