(b) moduleStatusMm group (1/7)
This group consists of three tables: mmStatusTable for the entire information on
the management module, mmVoltageTable for the voltage sensor information on
the management module, and mmTemperatureTable for the temperature sensor
information on the management module
Object
No
identifier
1
moduleStatus
Mm
2
mmStatusTabl
e
3
mmStatusEntr
y
4
mmStatusInde
x
5
mmStatusSlot
num
6
mmStatusHeal
thStatus
7
mmStatusPow
erStatus
(*1)
"unknown" is shown in the process of setting redundancy, or when no management
module is installed or the status cannot be obtained.
(*2)
"unknown" is shown when no management module is installed or the status cannot be
obtained. "power-off" is shown after executing Software Defined Networking (SDN) in
the process of setting redundancy.
(*3)
"0" is shown as the number of sensor when no management module is installed.
(*4)
"Not install" is shown if no management module is installed or redundancy setting is on
the process; "Cannot get data" is shown if the data cannot be obtained.
(*5)
"0" is shown if no management module is installed or redundancy setting is on the
process, if the data cannot be obtained, or if no sensor exists.
(*6)
"invalid" is shown if no management module is installed or redundancy setting is on the
process; "unknown" is shown if no data is obtained".
OID
Syntax
.1.3.6.1.4.1.1
Not-
16.5.39.3.3
Accessible
.1.3.6.1.4.1.1
Not-
16.5.39.3.3.1
Accessible
.1.3.6.1.4.1.1
Not-
16.5.39.3.3.1
Accessible
.1
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.1
.1.1
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.1
.1.2
.1.3.6.1.4.1.1
INTEGER
16.5.39.3.3.1
.1.3
.1.3.6.1.4.1.1
INTEGER
16.5.39.3.3.1
.1.4
1668
Access
Description
NA
Shows the management
module status.
NA
Shows the table of information
on the management module
status.
NA
Shows the table entry
describing the information on
the management module
status.
RO
Shows the index value ranging
from 1 to chassisCapacityMm
to identify the table entry.
RO
Shows the management
module slot number
corresponding to the index
shown in #4, ranging from 0 to
chassisCapacityMm–1.
RO
Shows the status of the
management module in the slot
shown in #5. One of the
following messages is shown.
(*1)
1: normal
2: fail
3: unknown
RO
Shows the status of the
management module installed
in the slot shown in #5. One of
the following messages is
shown. (*2)
1: power-off
2: power-on
3: unknown
4: booting
5: shutdown