Hitachi Compute Blade 2000 User Manual page 1690

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(a) moduleStatusBlade group (11/34)
Object
No
identifier
77
bladeVoltSe
.1.3.6.1.4.1.11
nsor21Name
6.5.39.3.2.2.1.
62
78
bladeVoltSe
.1.3.6.1.4.1.11
nsor21Value
6.5.39.3.2.2.1.
63
79
bladeVoltSe
.1.3.6.1.4.1.11
nsor21Valid
6.5.39.3.2.2.1.
64
80
bladeVoltSe
.1.3.6.1.4.1.11
nsor22Name
6.5.39.3.2.2.1.
65
81
bladeVoltSe
.1.3.6.1.4.1.11
nsor22Value
6.5.39.3.2.2.1.
66
82
bladeVoltSe
.1.3.6.1.4.1.11
nsor22Valid
6.5.39.3.2.2.1.
67
83
bladeVoltSe
.1.3.6.1.4.1.11
nsor23Name
6.5.39.3.2.2.1.
68
84
bladeVoltSe
.1.3.6.1.4.1.11
nsor23Value
6.5.39.3.2.2.1.
69
(*1)
The reply is "unknown", if no server blade is installed or the status cannot be obtained.
(*2)
A value that the server blade obtains from a voltage and temperature sensor is shown.
"0" is shown if no server blade or no sensor is installed.
(*3)
The reply is "normal" if no server blade is installed or the server blade power is off.
(*4)
"Not install" is shown if no server blade is installed; "Not support" is shown if a server
blade is installed without any sensor; "Cannot get data" is shown if the data cannot be
obtained.
(*5)
The response is "0" if no server blade or no sensor is installed. Obtain the MIB object of
the next OID, and determine whether or not the replied value is valid.
(*6)
"invalid" is shown if no server blade or no sensor is installed; "unknown" is shown if no
information can be obtained".
OID
Syntax
Display
String
Integer32
INTEGER
Display
String
Integer32
INTEGER
Display
String
Integer32
1639
Access
Description
RO
Shows the voltage sensor
name for the server blade in
the slot shown in #5. (*4)
RO
Shows the voltage value of the
server blade in the slot shown
in #5. (*5) The value is shown
using the unit of 0.1V. The
actual value is one-tenth of the
response value.
RO
Shows the voltage value
validity of the server blade in
the slot shown in #5. One of the
following values is shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the server blade in
the slot shown in #5. (*4)
RO
Shows the voltage value of the
server blade in the slot shown
in #5. (*5) The value is shown
using the unit of 0.1V. The
actual value is one-tenth of the
response value.
RO
Shows the voltage value
validity of the server blade in
the slot shown in #5. One of the
following values is shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the server blade in
the slot shown in #5. (*4)
RO
Shows the voltage value of the
server blade in the slot shown
in #5. (*5) The value is shown
using the unit of 0.1V. The
actual value is one-tenth of the
response value.