To make available the RS port of PN-AP00-B/PN-AP00-D card (with MRCA program):
START
CMDD01
Set interface condition for PN-AP00-B/
PN-AP00-D with MRCA program RS port.
NOTE:
CMDD10
To change the interface condition of each port
set by CMDD01, assign the attribute data, ac-
cording to the PMS.
END
DESCRIPTION
AP00 INITIAL
When setting the second data to 12, the initial data of CMDD10>X00, X01, X02, X03, X04,
X05 is set automatically.
AP00 INITIAL
HOTEL SYSTEM PROGRAMMING
PROPERTY MANAGEMENT SYSTEM INTERFACE
(1)
101 (Port 1)
103 (Port 3)
(2)
00 : Not used
12 : External Printer
(1)
X00: Equipment Type Connected to Port 1,
3
X
: 1, 3: Port 1, 3
(2)
6 : External Printer 0
(1)
X01: Data Speed for Port 1, 3
X
: 1, 3: Port 1, 3
(2)
1 : 300 bps
2 : 1200 bps
3 : 2400 bps
4 : 4800 bps
5 : 9600 bps
(1)
X02: Stop Bit Length for Port 1, 3
X
: 1, 3: Port 1, 3
(2)
0 : 1 bit
1 : 1.5 bits
2 : 2 bits
(1)
X03: Data Length for Port 1, 3
X
: 1, 3: Port 1, 3
(2)
0 : 7 bits
1 : 8 bits
(1)
X04: Parity for Port 1, 3
X
: 1, 3: Port 1, 3
(2)
0 : No Parity
1 : Even Parity
2 : Odd Parity
(1)
X05: Printer Digit Number for Port 1, 3
X
: 1, 3: Port 1, 3
(2)
0 : 80 digits
1 : 20 digits