When an External Key for Day/Night Mode
CM14
change or Class of Service change is required,
assign the DK card to required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
The DK card number must be as-
signed to the first LEN (level 0) and
the third LEN (Level 2).
CM08
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
CM61
To provide external keys for Day/Night Mode
change or Class of Service change, assign a
Tenant number to the DK card.
CM62
Specify the Tenants to be handled by each AT-
TCON Group.
B
DESCRIPTION
INITIAL
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
E900-E963 : DK Card No.
For FP No. 00: E900-E915
For FP No. 01: E916-E931
For FP No. 02: E932-E947
For FP No. 03: E948-E963
NOTE 2:
(1)
700
(2)
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
Y=00
(1)
XX Z
XX : 00-31: DK Card No. assigned by
CM10/CM14 (E900-E963)
Z : 0-3: Circuit No.
633: MP Built-in External Key Interface
(2)
00-63: Tenant No.
Y=0-3 ATT Group 0-3 assigned by CM60
Y=00
(1)
00-63: Tenant No.
(2)
0 : To handle
1 : Not handled
– 686 –
TENANT SERVICE
DATA
Circuit No. 3 of E963 is used for
built-in External Key Interface of
MP card by setting CM61.
NWA-008845-001 Rev.5.0