Hotel/Motel Toll Restriction Change-Guest Station - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

HOTEL/MOTEL TOLL RESTRICTION CHANGE-GUEST STATION

[Series 3900 software required]
PROGRAMMING
START
CM13
Specify the kind of station.
CM12
Assign Service Restriction Class A to required
guest station.
CM15
Allow Room Status Code setting (Room Cut-
off, Trunk Restriction class change).
CM12
Assign the Charging Station Service Class
number to each station.
CMDD04
Execute the operation set by CMDD31 is exe-
cuted simultaneously when Room Status Code
is set/changed.
CMDD01
Assign Room Status Code set by Check In op-
eration.
Assign Room Status Code set by Check Out
operation.
A
DESCRIPTION
HOTEL SYSTEM PROGRAMMING
HOTEL/MOTEL TOLL RESTRICTION CHANGE-GUEST STATION
Y=51
(1)
X-XXXXXX: Station No.
(2)
0 : Administrative Station
1 : Guest Station
Y=02
(1)
X-XXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=222
(1)
00-15: Service Restriction Class A as-
(2)
1: Allow
Y=45
(1)
X-XXXXXXXX: Station No.
(2)
00-15 : Service Class No.
(1)
XX 18
XX: Service Class No. assigned by CM12
Y=45
(2)
1: To execute
(1)
12
(2)
0 : Not used
1-8 : Room Status Code 1-8
(1)
13
(2)
0 : Not used
1-8 : Room Status Code 1-8
– 807 –
DATA
signed by CM12 Y=02
NWA-008845-001 Rev.5.0
32ch2001.fm
JUNE/01/2007