Station Hunting-Secretarial - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

STATION HUNTING-SECRETARIAL

PROGRAMMING
START
CM18
Assign a secretary station serial number to
each Station Hunting group.
NOTE:
CM19
Assign a station number to each secretary sta-
tion serial number assigned by CM18 Y=2.
Specify the Hunting capability of each secre-
tary station.
Set up the order of Secretary Hunting.
Assign secretary station serial numbers, one by
one, in order of the desired Secretary Hunting,
as shown below.
1st Operation
2nd Operation
CM08
Allow or restrict the ability to set Station Hunt-
ing-Secretarial for a station with Do Not Dis-
turb set.
END
DESCRIPTION
A maximum of 31 stations can be
members of the Secretarial Hunt
group.
(1) Station Serial No. A
(2) Station Serial No. B
(1) Station Serial No. B
(2) Station Serial No. C
Y=2
(1)
X-XXXXXXXX: Pilot Station No. (Termi-
(2)
00-30: Secretary Station Serial No.
Y=0
(1)
00-30: Secretary Station Serial No.
(2)
X-XXXXXXXX: Secretary Station No.
Y=1
(1)
00-30: Secretary Station Serial No.
(2)
5: Hunting (As per CM19 Y=2)
7: No hunting
Y=2
(1)
00-30: Secretary Station Serial No. (A)
(2)
00-30: Secretary Station Serial No. (B)
(1)
240
(2)
0 : Allow
1 : Restricted
– 614 –
STATION HUNTING
STATION HUNTING-SECRETARIAL
DATA
nal)/All Member Station
No. (Circular)
NWA-008845-001 Rev.5.0
32ch1010.fm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents