Philips Sopho 2000 IPS User Manual page 710

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

D
CM35
Specify the desired Station Ringing Cadence.
Specify the Ringer Tone Pattern of the D
each trunk route.
Y=34
0
1
2
3
E
DESCRIPTION
Y=164: 0
Ringer Tone Pattern 3
Ringer Tone Pattern 6
Ringer Tone Pattern 5
Ringer Tone Pattern 4
Y=46 DTMF Sender Release Timing
(1)
00-63: Trunk Route No.
(2)
0 : 2 seconds
1 : 4 seconds
2 : 6 seconds
3 : 8 seconds
4 : 12 seconds
5 : 14 seconds
6 : 16 seconds
7 : 10 seconds
Y=33 Ringing Cadence
(1)
00-63: Trunk Route No.
(2)
2 : 1 second ON-2 seconds OFF
3 : 2 seconds ON-4 seconds OFF
To make this data assignment effective en-
ter the data "1" for CM08>180.
term
to
Y=34, 164 Ringer Tone Pattern
(1)
00-63: Trunk Route No.
(2)
See the table below.
[Series 3200 R6.1 software required]
– 692 –
TIE LINES
DATA
Y=164: 1
Ringer Tone Pattern 0
Ringer Tone Pattern 1
Ringer Tone Pattern 2
Ringer Tone Pattern 7
NWA-008845-001 Rev.5.0