AUTOMATIC RECALL

PROGRAMMING
START
CM41
Specify the timing for AUTOMATIC RE-
CALL.
If no data is set, the following timing will be
applied:
Attendant Recall
Non Exclusive Hold : 60-64 seconds
Exclusive Hold
Transfer Recall
Attendant Hold Recall: 31.2-33.6 seconds
Camp-On Recall
END
DESCRIPTION
: 31.2-33.6 seconds
: 236-240 seconds
: 24-28 seconds
: 24-32 seconds
Y=0
(1)
00: Attendant Recall
(2)
01-14: 2.4-33.6 seconds
15-24: 38.4-124.8 seconds
(1)
05: Non Exclusive Hold
(2)
01-98: 4-392 seconds
99
: Recall is not performed
(1)
06: Exclusive Hold
(2)
01-98: 4-392 seconds
99
: Recall is not performed
(1)
07: Transfer Recall
(2)
01-30: 4-120 seconds
(1)
11: Attendant Hold Recall
(2)
01-14: 2.4-33.6 seconds
15-24: 38.4-124.8 seconds
(1)
26: Camp-On Recall
(2)
01-15: 16-128 seconds
– 127 –
AUTOMATIC RECALL
DATA
(2.4 second increments)
(9.6 second increments)
(4 second increments)
(4 second increments)
(4 second increments)
(2.4 second increments)
(9.6 second increments)
(8 second increments)