MESSAGE WAITING

PROGRAMMING
Refer to the DSS/BLF Console feature to program the DSS/BLF as a Message Front Station.
START
CM12
Assign Service Restriction Class A for Mes-
sage Waiting to required stations as shown be-
low.
CM15
Allow Message Waiting in Service Restriction
Class A assigned by CM12 Y=02.
STATION/ADMINISTRATIVE
Station w/o MW Lamp
Station with MW Lamp
Administrative station
CM13
Provide each station with Message Waiting.
term
(D
or Single-Line Telephone with Message
Waiting Lamp)
CM20
Assign an Access Code for Message Waiting
Set/Reset/Retrieve.
CM51
Assign the Message Front destination of the
MW retrieve call from the station to which
Message Waiting is set.
By pressing MW Retrieve access code or MW
term
key on D
tion.
A
DESCRIPTION
CM15
Y=24
0
0
1
, the call is routed to the destina-
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=24 Administrative station allowing
Message Waiting Set/Reset to station
Y=40 Station setting MW
(1)
00-15: Service Restriction Class A
CM15
(2)
0 : Restricted
Y=40
1 : Allow
0
1
0
Y=03
(1)
X-XXXXXXXX: Station No.
(2)
0: To provide
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A040: MW Lamp Control Set
A041: MW Lamp Control Reset
A147: MW Retrieve
Y=15
(1)
00-63: Tenant No. to which MW set D
(2)
X-XXXXXXXX: Message Front Station
E000
– 477 –
MESSAGE WAITING
DATA