For Direct Inward Dialing calls
• To distinguish by the trunk route
START
CM08
Specify the interval of ringing tones for Direct
Inward Dialing calls.
END
• To distinguish by the terminating DID number
START
CM08
Assign the interval of ringing tones as "As per
CM76 Y=22".
CM76
Specify the interval of ringing tones on DID
calls.
For this assignment, do not set CM76 Y=22 to
3 (As per CM35 Y=33 (D
END
DESCRIPTION
DESCRIPTION
term
or SLT)).
(1)
180
(2)
0 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
1 : As per CM35 Y=33
(1)
180
(2)
1 : As per CM76 Y=22
Y=22
(1)
000-999: Number Conversion Block No.
(2)
0: 0.5 seconds ON-0.5 seconds OFF
term
(D
1.0 second ON-2.0 seconds OFF (SLT)
1: 0.5 seconds ON-0.5 seconds OFF-
0.5 seconds ON-1.5 seconds OFF
term
(D
0.4 seconds ON-0.2 seconds OFF-
0.4 seconds ON-2.0 seconds OFF (SLT)
2: 1.0 second ON-2.0 seconds OFF (D
or SLT)
– 328 –
DISTINCTIVE RINGING
DATA
DATA
assigned by CM76 Y=00/90
)
)