Timed Reminder - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

TIMED REMINDER

PROGRAMMING
To provide the internal Music Source on the MP card:
START
CM12
Assign Service Restriction Class A for Timed
Reminder to required stations.
CM15
Allow Timed Reminder in Service Restriction
Class A assigned by CM12 Y=02.
CM20
Assign the access code for Timed Reminder
set and cancel.
CM48
Designate the type of tone source to be con-
nected when answering a Timed Reminder
call.
CM90
Assign the Timed Reminder feature access key
term
to a D
, if required.
CM08
Specify the timing for Timed Reminder Start.
CM41
Specify the ringing duration of a Timed Re-
minder call.
A
DESCRIPTION
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class A
Y=13
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code (5*, 5#)
(2)
A024: Timed Reminder Set
A025: Timed Reminder Cancel
Y=1
(1)
00: Tone Source of Timed Reminder
(2)
1400: Hold Tone Source on MP card
Y=00
(1)
My Line No. +
(2)
F0024
(1)
228: Timed Reminder Start timing
(2)
0 : At preset time
1 : Before 5 minutes of preset time
Y=0
(1)
23
(2)
02-14: 8-56 seconds
If no data is set, the default setting is 28-32 sec-
onds.
– 701 –
TIMED REMINDER
DATA
signed by CM12 Y=02
,
+ Key No.
(4 second increments)
NWA-008845-001 Rev.5.0